Camera settings
46
Siemens AB
Security Products
05.2014
Upload Image by FTP
Select this item and the administrator can assign a FTP site and configure various
parameters. When motion is detected, event images will be uploaded to the
appointed FTP site.
<Pre-trigger buffer> function allows users to check what happened to cause the
trigger. The <Pre-trigger buffer> frame rate could be pre-determined. On the
other hand, <Post-trigger buffer> is for users to upload certain amount of im-
ages after motion event occurs.
NOTE:
Normally the setting range of the <Pre-trigger buffer> is 1 to 20. However,
the setting range will change accordingly if the frame rate of MJPEG on the
<Video Frame Rate> setting page is 6 or smaller.
Check the box <Continue image upload> to upload the triggered images during
certain time or keep uploading until the trigger is off. Select <Upload for __
sec> and enter the duration in the blank. The images of the duration will be
uploaded to FTP when the motion event occurs. The setting range is from 1
to 9999 seconds. Select <Upload during the trigger active> to make the im-
ages keep being uploaded to FTP during the trigger active until the event
stops. Set the Image frequency as the upload frame rate. The setting range is
from 1 frame to 15 frames.
NOTE:
Make sure FTP configuration has been completed. Refer to
FTP
for further
details.
Upload Image by E-mail
Select this item and the administrator can assign an E-mail address and configure
various parameters. When motion is detected, event images will be sent to
the appointed E-mail address.
<Pre-trigger buffer> function allows users to check what happened to cause the
trigger. The <Pre-trigger buffer> frame rate could be pre-determined. On the
other hand, <Post-trigger buffer> is for users to upload certain amount of im-
ages after the motion event occurs.
NOTE:
Normally the setting range of the <Pre-trigger buffer> is 1 to 20. However,
the setting range will change accordingly if the frame rate of MJPEG on the
<Video Frame Rate> setting page is 6 or smaller.
Check the box <Continue image upload> to upload the triggered images during
certain time or keep uploading until the trigger is off. Select <Upload for __
sec> and enter the duration in the blank. The images of the duration will be
uploading by E-mail when the motion event occurs. The setting range is from
1 to 9999 seconds. Select <Upload during the trigger active> to make the im-
ages keep being uploaded to E-mail during the trigger active until the event
stops. Set the Image frequency as the upload frame rate. The setting range is
from 1 frame to 15 frames.
NOTE:
Make sure SMTP configuration has been completed. Refer to
for fur-
ther details.
Send HTTP notification
Check this item and select the destination HTTP address. Then specify the pa-
rameters for event notifications by <Motion Detection> triggered. When a mo-
tion is detected, the HTTP notification will be sent to the specified HTTP
server.
For instance, if the custom parameter is set as
“
action=1&group=2
”, and the HTTP
server name is
“
http://192.168.0.10/admin.php
”, the notification will be sent to
HTTP server as
“
http://192.168.0.10/admin.php? action=1&group=2
” when
alarm is triggered.