s
Operating manual
22
continuous process (continuous material flow), you must activate Auto
Reset. Limit 1 will then be ignored. Sampling will continue (restarting au-
tomatically and producing temperature readings cyclically) as long as
Limit 2 is exceeded for the time period defined by
T.DEL.
Parameter
Function
Autoreset (
A.RST
):
Autoreset on/off
Parameter Set Li2 check on tAct [
CH.L.2
]
When this parameter is set to ON (
CH.L.2
=on), the detected tempera-
ture must exceed Limit 2 during the entire measuring time (
TACT
) in
order for the pyrometer to generate a valid temperature reading. The
measurement is discarded when the value falls below Limit 2.
The display shows
„
----
“
Parameter
Function
Set Li2 check on tAct
(
CH.L.2
)
on/off
16
Setting Parameters at the device
In addition to the configuration possibilities described, many parameters
can be adjusted at the rear panel using push buttons. These settings can
be accessed via configuration layers.
16.1 Configuration layers
The configuration layers are structured as follows:
C001
Temperature measurement two-colour/ratio mode
C002
Temperature measurement lambda 1
C003
Temperature measurement lambda 2
C010
I/O configuration (LED / Buzzer)
C011
General function
C020
Display temperature readings
The following chart lists all parameters. In the factory default configura-
tion, certain parameters and configuration layers will not be accessible
by control key. This is meant to simplify pyrometer operation for the user.
These parameters are indicated by
. If required, remote access to these
parameters can be enabled via PC interface or at configuration layer
C011
. Open the user calibration menu (Menu mode: Full).
Some parameter settings will be hidden if their basic function has been
deactivated. For example, you will not be able to adjust the smoothing
Summary of Contents for Ardoptix PT 140 AF1
Page 1: ...Two colour Pyrometer PT 14x 7MC3040 Operating Manual 03 2017 ...
Page 2: ......
Page 3: ...Two colour Pyrometer PT Ident Nr 106 7393 PT14x_si_en doc Stand 21 03 2017 830 hm 810 het ...
Page 8: ...s Operating manual ...
Page 56: ...s Operating manual 48 29 Dimensions ...
Page 63: ...s Operating manual 55 ...
Page 64: ......
Page 65: ......
Page 66: ......
Page 67: ......