51
Operating instructions
7MC3052-1AC63
Temperature range
650 - 1600 °C
Sensor
Double Si
Spectral sensitivity
0.95 / 1.05 µm
Focus distance
Target spot diameter
1000 mm
18.5 x 2.7 mm
Analogue output
0(4) - 20 mA linear, switchable, scalable (≥ 50 K)
Resolution current output
0.2 K + 0.03 % of selected range
Resolution temp. reading
1 K
Response time t
90
≤ 10 ms (for T > 750 °C)
Repeatability
3 K
Measurement uncertainty
1.5 % of temp. reading [°C]
Temperature coefficient
0.05 %/K of temp. reading / K
(deviation to Tu = 23 °C)
Ambient temperature
0 - 65 °C in sum of load currents
Do1 and Do2 ≤ 150 mA, otherwise 0 - 60 °C
Current consumption
≤ 75 mA at 24 V DC without load current
Dimensions
M30 x 235 mm (without plug)
Target diameter [mm]
Energy
Target distance [mm]
LED
90 %
76.0 / 32.5
13.5 / 6.3
16.1 / 8.2
22.0 / 7.5
18.5 / 2.7
35.5 / 13.8
34.6 / 10.9
49.0 / 20.0
50.6 / 19.0
62.5 / 26.2
66.6 / 27.2
82.7/ 35.3
Ø 5
Ø 13.6
0
500
1000
1500
2000
2500
3000