48
Operating instructions
7MC3052-1AF66
Temperature range
700 - 1800 °C
Sensor
Double Si
Spectral sensitivity
0.95 / 1.05 µm
Focus distance
Target spot diameter
1800 mm
8 mm
Analogue output
0(4) - 20 mA linear, switchable, scalable (≥ 50 K)
Resolution current output
0.2 K + 0.03 % of selected range
Resolution temp. reading
1 K
Response time t
90
≤ 10 ms (for T > 800 °C)
Repeatability
2 K
Measurement uncertainty
1.0 % of temp. reading [°C] plus 3.0 K
Temperature coefficient
0.05 %/K of temp. reading / K
(deviation to Tu = 23 °C)
Ambient temperature
0 - 65 °C
Current consumption
≤ 50 mA at 24 V DC without load current
Dimensions
M30 x 200 mm (without plug)
Target diameter [mm]
Energy
Target distance [m]
0
0.1 0.2 0.3 0.4 0.5
1
1.5
2
2.5
3
5
4.5
4
3.5
9.2 9.3 9.4 9.5 9.7 9.8 10.4 10.9 11.5 17
22
43
37
32
27
9.2 9.4 9.6 9.8
10 10.2 11.1 12.1 13
19
24
46
41
35
30
95 %
90 %
PA 41.03
(2.0 m)