45
Operating instructions
7MC3052-1AC66
Temperature range
700 - 1800 °C
Sensor
Double Si
Spectral sensitivity
0.95 / 1.05 µm
Focus distance
Target spot diameter
1080 mm
5.6 mm
Analogue output
0(4) - 20 mA linear, switchable, scalable (≥ 50 K)
Resolution current output
0.2 K + 0.03 % of selected range
Resolution temp. reading
1 K
Response time t
90
≤ 10 ms (for T > 800 °C)
Repeatability
2 K
Measurement uncertainty
1.0 % of temp. reading [°C] plus 3.0 K
Temperature coefficient
0.05 %/K of temp. reading / K
(deviation to Tu = 23 °C)
Ambient temperature
0 - 65 °C
Current consumption
≤ 50 mA at 24 V DC without load current
Dimensions
M30 x 200 mm (without plug)
Target diameter [mm]
Energy
Target distance [m]
0
0.1 0.2 0.3 0.4 0.5
1.08
2
2.5
3
5
4.5
4
3.5
21.4 19.9 18.5 17.0 15.5 14.1
5.6
29
41
54
104
91
79
66
21.4 20.0 18.6 17.2 15.8 14.4
6.2
30
43
55
106
94
81
68
95 %
90 %
PKS21.01