Maintenance
7.3 Corrective Maintenance
A5E00177602A AD
Siemens AG Operating Instructions 2.02 1PH728
65
①
Bearing cap end face
②
Rotary shaft seal
③
Seat of shaft
The correct axial position of the rotary shaft seal is reached when the outer edges of the
bearing cap end face ① and rotary shaft seal ② are flush.
[ID: 375.01]
7.3.4
Screw-type connections
Tightening torque for screwed union connections
The screwed union connections with metal contact surfaces (end shields, active bearing
parts, terminal box parts bolted onto the stator frame) should be tightened to the following
torque with a tolerance of ± 10 %, depending on the thread size.
Table 7-4
Tightening torque for screwed union connections
Thread size
M6
M8
M10
M12
M16
M20
M24
Tightening torque [Nm]
8
20
40
70
170
340
600
Please refer to the relevant sections and drawings for all other tightening torques (electrical
connections and bolted connections for parts with flat gaskets).
Bolt locking devices
Nuts or bolts that are mounted together with locking, resilient and/or force-distributing
elements (e.g., safety plates, spring-lock washers, etc.) must be refitted together with
identical, fully functional elements.
Always replace keyed elements.
[ID: 379.01]
7.3.5
Replacing the sensor module
Only trained service engineers are authorized to replace the sensor module.
Siemens Hardware
Summary of Contents for 1PH728
Page 2: ...17 03 2008 10 00 ...
Page 8: ......
Page 16: ......
Page 24: ......
Page 48: ......
Page 72: ......
Page 76: ......
Page 78: ......
Page 79: ...Siemens Hardware ...
Page 80: ......
Page 81: ...AB U161 Konformitätserklärung AB U151 Herstellererklärung Siemens Hardware ...
Page 82: ......