A5E00177602A AD
Siemens AG Operating Instructions 2.02 1PH728
47
Faults
6
6.1
Fault diagnosis table
Diagnosis table for mechanical and electrical faults
The tables below list general faults caused by mechanical and electrical influences.
Table 6-1
Diagnosis table for mechanical faults
Overview of mechanical faults
Mechanical fault characteristics
- rubbing/grinding noise
- significant temperature rise
- radial vibration
- axial vibration
Possible causes of faults
Remedial measures
1)
↴
↴
↴
↴
- Rotating parts rubbing/grinding
Determine cause and adjust parts
x
- Air supply restricted,
filter dirty,
possibly wrong direction of rotation of fan
Check air passages,
clean filter, replace fan if necessary
x
- Rotor not balanced
Decouple rotor and rebalance
x
- Rotor out of true, shaft bent
Consult the manufacturer
x
- Poor alignment
Align motor unit,
check coupling
2)
x x
- Coupled motor not balanced
Rebalance coupled motor
x
- Shocks from coupled motor
Check coupled motor
x
- Imbalance originating from gearing
Adjust/repair gearing
x x
- Resonance with the foundation
After consultation, reinforce foundations
x x
- Changes in foundation
Determine cause of changes,
eliminate if necessary; realign motor
x x
1)
As well as eliminating the cause of the fault (as described under "Remedial measures"), you must also rectify any
damage the motor may have suffered.
2)
Take into account possible changes due to a rise in temperature.
Siemens Hardware
Summary of Contents for 1PH728
Page 2: ...17 03 2008 10 00 ...
Page 8: ......
Page 16: ......
Page 24: ......
Page 48: ......
Page 72: ......
Page 76: ......
Page 78: ......
Page 79: ...Siemens Hardware ...
Page 80: ......
Page 81: ...AB U161 Konformitätserklärung AB U151 Herstellererklärung Siemens Hardware ...
Page 82: ......