Scanning range diagram
0
Scanning range in m (feet)
1
Scanning range in m (feet)
1
0
0°
6
10
10
6
10
10
90°
-90°
Scanning range max. 10 m (32.81 ft)
2
Scanning range 2.8 m to 3 m (9.19 ft to 9.84 ft)
for objects with 10% remission, dependent on the angle
3
‒120°
120°
240°
2
2
2
2
6
6
(6.56)
(19.69)
(32.81)
(6.56)
(19.69)
(32.81)
(32.81)
(19.69)
(6.56)
(6.56)
(19.69)
(32.81)
Figure 12: Scanning range diagram, TiM240
1
Scanning range in m (feet)
2
Scanning range max. 10 m (32.81 ft)
3
Scanning range 2.8 m to 3 m (9.19 ft to 9.84 ft) for objects with 10% remission, depen‐
dent on the angle
10.2
Performance
Device type
TiM2xx
Response time
Typ. ≥ 70 ms
Detectable object shape
Almost any
Systematic error
± 40 mm
1
Statistical error
30 mm
1
Scan field flatness
± 3°
1
Typical value; actual value depends on ambient conditions
10.3
Interfaces
Device type
TiM2xx
Ethernet
Function: Configuration, Data output
Digital outputs
1 (push-pull, each ≤ 100 mA, not electrically isolated from the sup‐
ply voltage)
Delay time
70 ms ... 30,000 ms (programmable)
Optical indicators
2 LEDs (green, red)
10
TECHNICAL DATA
32
O P E R A T I N G I N S T R U C T I O N S | TiM2xx
8025019/190A/2020-08 | SICK
Subject to change without notice