Indicador LED / padrão de er‐
ro /
LED indicator/fault pattern
Causa /
Cause
Medida /
Measures
distance between the sender
and the receiver, and check
against graphic H. / Check
sensing range and adjust if
necessary; see graphic H. /
With health output: Check the
power supply, check all electri‐
cal connections (cables and
plug connections).
LED amarelo aceso, nenhum
objeto no caminho óptico /
Yellow LED lights up, no object
in the path of the beam
O feixe de luz de uma barreira
de luz unidirecional está inci‐
dindo sobre o receptor de
uma outra barreira de luz uni‐
direcional (vizinha) /
The beam of light of a photo‐
electric through-beam sensor
hits the receiver of another
(neighboring) photoelectric
through-beam sensor
Trocar a disposição do sensor
e do receptor a cada duas
barreiras de luz unidirecionais
ou manter distância suficiente
entre as barreira de luz unidi‐
recionais. /
Swap the sender and receiver
arrangement at every se‐
cond photoelectric through-be‐
am sensor and ensure that
there is sufficient distance
between the through-beam
photoelectric sensors
35
Desmontagem e descarte
O descarte do sensor deve ser efetuado de acordo com as normas aplicáveis específi‐
cas de cada país. No âmbito do descarte, deve-se procurar o aproveitamento dos mate‐
riais recicláveis contidos (principalmente dos metais nobres).
36
Manutenção
Os sensores SICK não requerem manutenção.
Recomendamos que se efetue em intervalos regulares
•
uma limpeza das superfícies ópticas
•
uma verificação das conexões roscadas e dos conectores
Não são permitidas modificações no aparelho.
Sujeito a alterações sem aviso prévio. As propriedades do produto e os dados técnicos
especificados não constituem nenhum certificado de garantia.
35
DESMONTAGEM E DESCARTE
28
8017854 | SICK
Subject to change without notice