5.4
Mounting the device
1.
Place device at mounting site.
2.
Fasten the device with at least two M6 screws (max. 6 Nm) and corresponding
washers on opposite sides of the device.
NOTICE
Use self-locking or lock nuts on mounting sites that are exposed to vibrations to
prevent the holding plates from loosening.
5.5
Mounting the device at a critical ambient temperature from 40 °C
NOTICE
To prevent damage to the device or the attached peripheral devices at high ambient
temperatures from 40 °C, the following extended installation conditions must be taken
into account when mounting the device.
Prerequisites
•
Aluminum profiles for mounting on the system (min. 40 x 40 mm and 500 mm in
length)
•
No direct sunlight and heat radiation
•
Distance to other components or housing walls: min. 100 mm
Installation steps
1.
Set device on aluminum profile.
2.
Fasten device with at least two M6 screws (max. 6 Nm) on opposite device sides
and corresponding washers.
NOTICE
Use self-locking or lock nuts on mounting sites that are exposed to vibrations to prevent
the holding plates from loosening.
MOUNTING
5
8023516/1BQH/2021-07-28 | SICK
O P E R A T I N G I N S T R U C T I O N S | SIM1004
15
Subject to change without notice