Detailed instructions on the SICK AppStudio as well as programming the device can be
found at
.
3.4
Preset Ethernet interfaces
NOTE
Preset IP addresses of the ETHERNET interfaces:
•
ETHERNET 1: 192.168.0.1
•
ETHERNET 2: 192.168.1.1
•
ETHERNET 3: 192.168.2.1
When expanding the 1 GigE interfaces with one or more Ethernet switches, it is essen‐
tial to use only jumbo-frame compatible 1 GigE switches. Switches limited to just
100 Mb/s do not support the data packet mode used by cameras and can cause
transmission errors.
Changing the IP addresses
The individual IP addresses can be changed using the Welcome app pre-installed in the
device or via the SICK PC tool SOPAS ET .
3
PRODUCT DESCRIPTION
12
O P E R A T I N G I N S T R U C T I O N S | SIM1004
8023516/1BQH/2021-07-28 | SICK
Subject to change without notice