![SICK S3000 Expert Operating Instructions Manual Download Page 79](http://html.mh-extra.com/html/sick/s3000-expert/s3000-expert_operating-instructions-manual_1264650079.webp)
Figure 65: SX0A-A0000D system plug
b
Depending on the application, use suitable cable entries on the top or rear.
b
Use EMC-compliant cable glands for the EFI cables.
Table 9: Use of the supplied cable entries
Cable entry
Cable diameter
Use
M20
6 mm … 12 mm
•
System cables (supply volt‐
age, outputs, static inputs)
M12 (only if supplied)
3 mm to 6.5 mm
•
•
•
RS-422 data cables
•
EFI
Table 10: Recommended wire cross-sections
Cable
Recommended wire cross-
sections
Shielded
System cables (supply voltage,
outputs, static inputs)
0.5 mm² … 1 mm², 9 … 17
wires
No
4 × 0.25 mm²
Yes
EFI
1 × 2 × 0.22 mm²
Yes
2 × 0.25 mm²
No
RS-422 data cables
4 × 0.25 mm²
Yes
1)
A shield is recommended if there are high EMC charges in the surroundings.