![SICK S3000 Expert Operating Instructions Manual Download Page 118](http://html.mh-extra.com/html/sick/s3000-expert/s3000-expert_operating-instructions-manual_1264650118.webp)
b
The annex to this document includes a checklist for review by the manufacturer
and installer. Use this checklist as a reference before commissioning the system
for the first time.
b
Document in a clear manner the settings for the safety laser scanner, and the
results of the testing during initial commissioning. For this purpose also print out
the complete configuration of the safety laser scanner (including protective field
shapes) and include these with the documentation.
NOTE
•
Use the
Create diagnostic dump...
function in the CDS (right click on the COM inter‐
face to which the safety laser scanner is connected). You can keep these data as a
backup and in this way document the state during initial commissioning at any
time.
•
Your SICK representative will be pleased to provide you with advice on initial com‐
missioning.
Further topics
•
"Checklist for initial commissioning and commissioning", page 169
8.4
Recommissioning
Overview
If the device has already been put into operation but has been replaced or exchanged
since then, the device automatically reads the saved configuration from the system
plug remaining on the machine.
No acceptance by qualified safety personnel is required after the configuration is read
from the system plug. The check as per the requirements for daily checking must, how‐
ever, be carried out.
7-segment display and LEDs after the power up sequence
Table 29: 7segment display during and after the power up sequence during recommissioning
Step
Display
Meaning
1
,
,
,
,
,
,
,
Power-up cycle, test of the 7-segment display. All segments
are activated consecutively.
2
Saved configuration invalid: Devices in the configuration
mode, no further steps taken
Waiting for partner device on the EFI
3
or
Device addressed as host or guest (only in an EFI system)
4
Device in dual field mode or dual protective field mode
Device in triple field mode
5
Waiting for valid inputs
A device connected via EFI reports a malfunction.
6
Waiting for Reset
Waiting for EDM
7
No display
Device is ready for operation
,
Device ready for operation but object in the first or second
protective field of the field set (in dual protective field mode)
8
COMMISSIONING
118
O P E R A T I N G I N S T R U C T I O N S | S3000
8009942/ZA18/2019-11-14 | SICK
Subject to change without notice