Name
Display
Description
Value
selection
Display
Initial
value
Description
don
Dark switching: The switching
output switches off when the
object is closer than the
taught sensing range.
Stb
The switching output Q1
issues the stability of the
measured value acquisition
(therefore corresponds to the
LED stability display). Light
switching functionality.
Std
The switching output Q1
issues the stability of the
measured value acquisition
(therefore corresponds to the
LED stability display). Dark
switching functionality.
AVG
AUG
Setting the moving arithmetic
average
1, 4, 16,
64, 256
64
64
Sets the number of values
across which a moving arith‐
metic average is established
when the signal is output.
This smooths the signal out‐
put. The possible values are
1, 4, 16, 64, or 256 (e.g., 1 =
no averaging, 256 = average
across 256 values)
RST
rSt
Reset to factory settings
NO, YES
no
X
No reset.
YES
Reset all values to factory set‐
tings with the exception of the
PNP/NPN selection.
DSP
dSP
Display settings
ON, OFF
on
X
Display shows display value in
cm.
oFF
Display switches off 30 sec‐
onds after an operating but‐
ton was last pressed.
DLY
dLY
Setting the time functions for
the switching outputs.
OFF, OFD,
OND, SHT
oFF
X
No time function activated.
oFd
Switch-off delay, adjustable
from 0 … 999 ms.
ond
Switch-on delay, adjustable
from 0 … 999 ms.
Sht
Single shot, adjustable from 0
… 999 ms.
Q_1
q_I
Distance assignment for
switching output Q1.
0 … 300
300
300
Value range 0 … 300
Q_2
q_2
Distance assignment for
switching output Q2.
0 … 300
300
300
Value range 0 … 300
Q_3
q_3
Distance assignment for
switching output Q3. (only in
5-pin devices)
0 … 300
300
300
Value range 0 … 300
OFS
oFS
Defines the offset of the
switching threshold (cm) dur‐
ing the teach-in, based on the
currently measured value.
-50 … +50
0
0
Value range -50 … +50
4
CONFIGURATION
10
8020034.17U4 | SICK
Subject to change without notice