64
8019897/V2-0/2017-12| SICK
O P E R A T I N G I N S T R U C T I O N S | PowerCEMS100
Subject to change without notice
12
SPECIFICATIONS
12.3
Technical data
Note
The exact device specifications and performance data of the product can
deviate and depend on the respective application and customer specification.
Measured variables
CH
4
, CO, CO
2
, NO, N
2
O, O
2
, SO
2
, further components on request
Measuring method
Extractive
Gas flow
60 l/h
With bypass pump:
≤
250 l/h
For short response times
Process temperature
≤
+1000 °C
Depending on sampling probe
Sample gas temperature
≤
+200 °C
Temperature at system cabinet inlet
Process gas humidity
Non-condensing
Ambient temperature
+5 °C ... +40 °C
With cooling unit: +5 °C ... +50 °C
Storage temperature
–20 °C ... +55 °C
Ambient humidity
≤
75 %
Relative humidity, non-condensing
Compliance
Approved for plants requiring approval
2001/80/EC (13
th
BimSchV)
2000/76/EC (17
th
BimSchV)
2006/95/ EC Low Voltage Directive
2008/108/EC Electromagnetic Compatibility
DIN EN 61439-1 and
DIN EN 61439-2 Low voltage switchgear assemblies
DIN EN 15267-3 Certification of automated measuring systems
DIN EN 14181 Stationary source emissions
Electrical safety
CE
IP classification
IP 54
With cooling unit: IP 44
Analog outputs
4 outputs:
0/2/4 ... 20 mA, 500
Ω
Electrically isolated
Analog inputs
2 inputs:
0/4 ... 20 mA, 100
Ω
Not electrically isolated
Digital outputs
8 potential-free outputs (changeover contacts):
34 V AC, 500 mA /48 V DC, 500 mA
Maximum quantity of outputs depends on the application
Digital inputs
8 inputs:
42 V
Maximum quantity of inputs depends on the application
Interfaces
RS-422 (option)
RS-485 (option)
Ethernet TCP/IP
Bus protocol
Modbus TCP
OPC
CAN