34
8019897/V2-0/2017-12| SICK
O P E R A T I N G I N S T R U C T I O N S | PowerCEMS100
Subject to change without notice
6
COMMISSIONING
Information on
operation / function of
the system cabinet
cooling unit
An additional door limit switch is normally fitted to avoid higher condensate levels when the
system cabinet door is open.
Opening and closing the system cabinet door prevents a possible cyclic operation.
Switching the cooling function off and on is automatically delayed. Refer to the Operating
Instructions of the cooling unit for duration and further details on the switching delay.
Avoid frequent, short starts of the cooling unit or opening the system cabinet door
frequently for short periods.
6.8
Commissioning of the heated gas sampling probe
▸
The sample gas probe is a system-specific / project-specific external functional unit
(option).
▸
Wait for the heating up time for the gas sampling probe to end (duration: approx.
2 hours.
▸
Check the setpoint setting on the built-in thermostat or on the external controller
(optional controlled heater).
▸
Make sure the built-in ball valve is closed on gas sampling probes with ball valve
(option).
Observe the relevant Operating / Assembly Instructions for the gas sampling
probe during commissioning.
See the Technical System Documentation for setpoint values.
DANGER
HOT SURFACES ON PROBES AND FILTERS
Serious burns.
▸
Wear protective gloves.
▸
Protect parts against unauthorized access.
DANGER
ESCAPING GAS DUE TO OVERPRESSURE IN THE GAS DUCT
Serious injuries of the eyes and respiratory system
▸
Regularly check the gas duct for leak tightness.
▸
Wear suitable respiratory equipment.
▸
Ensure adequate ventilation.
DANGER
EXPLOSIVE SAMPLE GAS
Serious injuries or death.
▸
Check the gas duct for leak tightness.
▸
Prevent ignitions parks (light switch, open fire).
▸
Ensure adequate ventilation.
DANGER
SAMPLE GASES DETRIMENTAL TO HEALTH
Serious injuries of the respiratory system or death.
▸
Wear suitable respiratory equipment.
▸
Ensure adequate ventilation.