23
8019897/V2-0/2017-12| SICK
O P E R A T I N G I N S T R U C T I O N S | PowerCEMS100
Subject to change without notice
TRANSPORT
4
4
Transport
▸
Use eye bolts / transport lugs on the cabinet roof.
▸
Only install the system using suitable lifting equipment (e.g. crane, sling chains, lifting
straps). Weight (
▸
Immediately after installation, secure the cabinet against falling over.
4.1
Removing the transport safety devices
▸
Check the system for transport safety devices and remove these.
4.2
Checking attachments and connections
▸
Check hose connections and screw fittings for tight seat.
4.3
Insert filter elements and bubbling frits
▸
To prevent damage during transport, some components are disassembled and delivered
in separate packing in the control cabinet.
Note
The system may only be transported and installed by qualified persons. The
device may only be installed and operated by skilled technicians who, based on
their technical training and knowledge as well as knowledge of the relevant
regulations, can assess and perform the tasks given and recognize and avoid
hazards.
DANGER
SUSPENDED LOADS
Danger through suspended loads. Serious injuries or death.
▸
Never stand under suspended loads.
▸
Special attention when lifting the loads.
▸
Comply with the lifting instructions to prevent head injuries and
other accidents.
▸
Use suitable lifting equipment.
▸
Wear protective helmet and safety boots.
Note
▸
Remove the transport safety devices from the control cabinet, filter and other
parts prior to commissioning.
Note
▸
Filter elements and bubbling frits must be installed and/or filled before
commissioning.