Operating Instructions
LMS500 Product Family
Commissioning and configuration
8013796/UL20/2010-09-27
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
61
Chapter
6
6.4
Initial commissioning
The LMS is adapted to the local measurement situation using SOPAS ET. For this purpose
a custom parameter set is created using SOPAS ET. The parameter set can either be loaded
initially from the device (upload) or it can be prepared independently.
The parameter set is then loaded into the LMS (download). This action is performed either
immediately (SOPAS ET option I
MMEDIATE
DOWNLOAD
) or manually (SOPAS ET command
D
OWNLOAD
ALL
PARAMETERS
TO
THE
DEVICE
).
Important
Once the configuration has been completed, the parameter set must be saved in the non-
volatile memory in the laser measurement system. In addition, the parameter set can be
saved as a project file (spr
F
file with configuration data) on the PC and archived.
Fig. 46:
Principle of data storage
Parameter set in the
LMS RAM
Parameter set saved in
non-volatile memory
Factory settings for the
LMS
RAM
EEPROM
ROM
Open project file with
current parameter set
RAM
Saved project file with
archived parameter set
(*.spr)
Hard disc
Upload
Download
LMS
PC with SOPAS ET
Summary of Contents for LMS500-20000 PRO Indoor