Electrical installation
48
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
8013796/UL20/2010-09-27
Operating Instructions
Laser Measurement Systems of the LMS500 Product Family
Chapter
5
5.2.1
Connections of the LMS500
“Ethernet” connection M12×4, socket
Terminal
Signal
Function
1
24 V SYS
Supply voltage LMS
2
GND SYS
Ground LMS
3
24 V EXT
4
GND EXT
5
OUT 1
Digital output 1
6
OUT 2
Digital output 2
7
OUT 3
Digital output 3
8
OUT 4
Digital output 4
9
OUT 5
Digital output 5
10
OUT 6
Digital output 6
11
CAN H
CAN-BUS High
12
GND CAN HST
Ground CAN host
13
CAN L
CAN-BUS Low
14
SHIELD
Shield
15
Reserved
Do not use!
16
Reserved
Do not use!
17
IN3
Digital input 3
18
IN4
Digital input 4
19
IN34EXT
20
IN12EXT
21
IN1
Digital input 1
22
IN2
Digital input 2
23
RTS TDP
24
TXD TDN
25
GND CAN HST
Ground CAN host
26
RXD RDN
27
CTS RDP
28
SHIELD
Shield
Tab. 9:
Terminal assignment of the LMS500
Pin
Signal
Function
1
Ethe
Ethernet interface
2
Ethe
Ethernet interface
3
Ethernet_TX–
Ethernet interface
4
Ethernet_RX–
Ethernet interface
Tab. 10:
Pin assignment of the “Ethernet” connection on the LMS500
3
2
4
1
Summary of Contents for LMS500-20000 PRO Indoor