Annex
84
© SICK AG · Division Auto Ident · Germany · Subject to change without notice
8013796/UL20/2010-09-27
Operating Instructions
Laser Measurement Systems of the LMS500 Product Family
Chapter
10
EventInfo
Defines whether event information is
output
uint_16
2
0
no event information
1
Output of the event
information
Ev
en
t
in
fo
rm
at
io
n
Event type
Fast digital input event
string
4
FDIN
Encoder position
Encoder position at the time of the
event, information in ticks
uint_32
4
00000000h
…
FFFFFFFFh
EventTime
Time since the LMS was switched on
in µs
uint_32
4
00000000h
0
FFFFFFFFh
4,294,967,295 µs
Angular position
Angular position of the LMS at the
time of the event, information in 1/
10,000 Grad
int_32
4
0
…
3,600,000
Message part
Description
Variable type
Length
(byte)
Value range
Message syntax IX:
Answer to the “Read scan data” request