22
8 007 487/ 10-10-99 Technical Description • LGT © SICK AG • Safety Systems • Germany • All rights reserved
Protective field height in mm
Device type
Order no.
150
300
450
600
750
900
1 013 413
1 013 414
1 013 415
1 013 416
1 013 417
1 013 418
1 013 419
1 013 420
1 013 421
1 013 422
1 013 423
1 013 424
11 Safety Light Screen LGT Selection
11 Safety Light Grid LGT Selection
11.1 LGT Selection table
LGTS 015-051
LGTE 015-051
LGTS 030-111
LGTE 030-111
LGTS 045-171
LGTE 045-171
LGTS 060-231
LGTE 060-231
LGTS 075-291
LGTE 075-291
LGTS 090-351
LGTE 090-351
The following procedure should be
used when selecting an active
optoelectronic protective device:
Action
Note
Regulations?
Protective zone
width?
Protective zone
height?
Resolution
The responsible authorities and profes-
sional associations can provide assistance
here.
The protective zone width is the width of
the area which is to be safeguarded. The
width must be selected in such a way that
the hazardous areas can only be accessed
through the protective zone.
The protective zone height must be
selected in such a way that the hazardous
areas can only be accessed through the
protective zone.
The resolution determines the safety
distance.
Refer to the relevant regulations,
standards and requirements for
the application.
Determine the required width of
the protective zone
Determine the required height of
the protective zone