8 Technical Data of LGT Safety Light Grid
8 Technical Data of LGT Safety Light Grid
1
) A power supply unit with safeguarded isolation
(SEL V, PEL V circuit) must be used.
2
) The voltage must not exceed or fall below the
limit values.
Caution: In the event of high-energy overvoltages
between DC supply and PE potential (
≥
0.5 kV)
a switch to AC supply and/or insulated mounting
of the sensor strips is recommended. In case of
interference also lay the sensor cables isolated
from the interfering cable duct.
3
) Cannot be shortened.
Main relay
1
1
2
2
V DC
A
50
0
100
150
200
250
10
1,0
0,1
1
1
2
2
VDC
A
10
100
300
200
10
1,0
0,1
Auxiliary relay
min.
typ.
max.
General system data
Protective field height
150 mm
900 mm
Protective field width
0.1 m
6 m
Resolution
30 mm
Wave length of the sender
880 nm
Protection class
1
Enclosure rating
Light grid
IP 65
Control unit
IP 54
or IP 20 (for cabinet installation)
Operating mode
with or without restart inhibit
Supply voltage U
V
1
)
DC
19.2 V
24 V
28.8 V
ripple
2
)
5 V
ss
or
AC
92 V
115 V
126.5 V
184 V
230 V
253 V
frequency
48 Hz
62 Hz
Power consumption
13 W
16 VA
Output
Main relay
resistive
4 A, 45 V DC
(see diagram)
inductive
4 A, 25 V DC
(see diagram)
Auxiliary relay
resistive
8 A, 55 V DC
(see diagram)
inductive
8 A, 15 V DC
(see diagram)
Protective zone status
surge-proof
100 mA
U
V
– 2,5 V (HIGH)
U
V
600
µ
A (I
Q
)
Dirt indicator
surge-proof
100 mA
U
V
– 2.5 V (HIGH)
U
V
600
µ
A (I
Q
)
Response time
50 ms
Length of connecting leads
see 11.2 selection table
3
)
Operating modes
0.1 mm
2
1.5 mm
2
Operating data
Safety category
type 2
Requirements
pr EN 50100
Operating temperature range
– 10
°
C
+ 55
°
C
Humidity range
15 %
95 %
Storage temperature range
– 25
°
C
+ 70
°
C
Dimensions
See 9 Dimensions
Housing colour
Cadmium yellow, RAL 10-21
Vibrostability
5 g, 10 ... 55 Hz to IEC 68-2-6
Shock resistance
10 g, 16 ms acc. IEC 68-2-29