19
8 007 487/ 10-10-99 Technical Description • LGT © SICK AG • Safety Systems • Germany • All rights reserved
9 Dimensions
9 Dimensions
LGT
No. of
Enclosure Prot. zone
type
beams length
height mm
a)
b)
0 1 5
5
1 8 5
1 5 5
0 3 0
1 1
3 3 5
3 0 5
0 4 5
1 7
4 8 5
4 5 5
0 6 0
2 3
6 3 5
6 0 5
0 7 5
2 9
7 8 5
7 5 5
0 9 0
3 5
9 3 5
9 0 5
32,5
259,5
409,5
559,5
709,5
859,5
0
ø 7,5
M5
2,8
10
15
30
2,8
a)
x
72,5
25
12,5
(159,5)
15
b)
51,5
only LGT 015
1
)
2
)
x = mounting holes
1)
Upper safety field limit is indicated by groove in housing
2)
Lower safety field limit is 15 mm from end of housing
Fig. 26. Dimensions of sender LGTS, receiver LGTE