CR-600  

Chattering Relay 

 

Accessory

The AE Techron 

CR 600 Chattering Re-

lay 

is a cost-effective, rugged yet elegant 

solution to the DO 160 Section 19.3.5 

“Spikes Induced into Interconnecting 

Cables” test requirement.
Internally built around a 50A high-cur

-

rent relay with two independent sets of 

contacts, the CR 600 was engineered for 

double the life before refurbishment.  
The CR 600 uses quick-connect, touch-

proof connectors to ensure efficient 

setup and a safe test environment. It also 

includes quick-clip test points for oscillo

-

scope monitoring of tests in progress.

When driven from an intermittent voltage 

source like the AE Techron DSR 100-

25 and utilizing test waveform, “Section 

19.3.5 CR 600”, the CR 600 output 

meets the voltage (600V), duration (50 

– 1000 µs) and repetition-period (0.2 to 

10 µs) requirements specified by the DO-

160 standard.

Application

The AE Techron CR-600 accessory was 

designed for use with AE Techron ampli

-

fiers to perform the Spikes Induced into 

Interconnecting Cables test as part of 

aviation test standards like RTCA DO160 

Section 19.3.5.

Unit Setup

Safety First 

Throughout these instructions, special 

emphasis is placed on good safety 

practices. The LIGHTNING FLASH 

Features 

• 

Coil Voltage: 24 VDC

• 

Coil Current: 84 mA

• 

Contact Rating: 30A

• 

Typical Pulse Voltage: >700 Vpp

• 

Includes oscilloscope connection 
points for voltage monitoring

and EXCLAIMATION POINT graphics 

are used to highlight certain topics that 

require extra precaution. 

Watch for These Symbols:

The lightning flash with the 

arrowhead symbol within an 

equilateral triangle is intended to 

alert the user to the presence of “danger

-

ous voltage” inside the product that may 

constitute a risk of electric shock.

The exclamation point within an 

equilateral triangle is intended 

to alert the user to the presence 

of important operating and maintenance 

instructions in the literature accompany

-

ing the product.

Important Safety Instructions

1. 

Read and keep these instructions. 

Follow all instructions and heed all 

warnings.

— INSTRUCTION SHEET —

For testing to these Specifications:

 

● DO 160 Section 19.3.5

Summary of Contents for CR-600

Page 1: ...was designed for use with AE Techron ampli fiers to perform the Spikes Induced into Interconnecting Cables test as part of aviation test standards like RTCA DO160 Section 19 3 5 Unit Setup Safety First Throughout these instructions special emphasis is placed on good safety practices The LIGHTNING FLASH Features Coil Voltage 24 VDC Coil Current 84 mA Contact Rating 30A Typical Pulse Voltage 700 Vpp...

Page 2: ... all servicing to qualified ser vice personnel Servicing is required when the apparatus has been dam aged in any way such as liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or mois ture does not operate normally or has been dropped 9 Do not remove product covers No user serviceable parts inside Refer servicing to qualified service personnel ...

Page 3: ... to the positive oscilloscope terminal the chattering pulse train will not occur This will not damage the unit and after corrections have been made normal operation can resume Operation 1 Configure your test system or signal generator power amplifier combi nation to apply a 28 VDC to the Amplifier Connections terminals of the CR 600 This will cause the chat tering pulse train to begin 2 Adjust the...

Page 4: ...ng to qualified service personnel Disconnect this product before cleaning Use a damp cloth for cleaning Clean the outside of the product only Figure 3 Example of output from the CR 600 when adjusted for a pulse sequence with an amplitude greater than or equal to 600 Vpp and a total duration of 50 to 1000 microseconds Figure 4 Example of output from the CR 600 when adjusted for a repetition period ...

Page 5: ...ts original packaging or a suitable alternative Replacement pack aging materials can be purchased for a nominal fee Please send all service units to the fol lowing address and be sure to include your Return Authorization Number on the box AE Techron Inc Attn Service Department RMA 2507 Warren Street Elkhart IN 46516 Specifications Performance Specifications Coil Voltage 24 VDC Coil Current 84 mA C...

Page 6: ... Nor do they cover every possible situation which may arise during installation operation or maintenance Information Accuracy The information provided in this manual was deemed accurate as of the publica tion date However updates to this infor mation may have occurred To obtain the latest information for your unit please visit the AE Techron website at www aetechron com Trademark Notice AE Techron...

Page 7: ...nal charge We will take corrective actions within a reasonable time of the date of receipt of the defective product If the repairs made by us are not satis factory notify us immediately SUMMARY OF WARRANTY AE TECHRON INC of Elkhart Indiana Warrantor warrants to you the ORIGI NAL COMMERCIAL PURCHASER and ANY SUBSEQUENT OWNER of each NEW AE TECHRON INC product for a period of one 1 year from the dat...

Page 8: ... of this warranty DESIGN CHANGES We reserve the right to change the design of any product from time to time without notice and with no obligation to make corresponding changes in products previously manufactured LEGAL REMEDIES OF PURCHASER There is no warranty that extends beyond the terms hereof This written warranty is given in lieu of any oral or implied warranties not contained herein We discl...

Reviews: