background image

RELAYS

External Signaling Relays

Aiphone Communication Systems  •  1700 130th Ave. N.E.  •  Bellevue, WA  98005

(425) 455-0510  •  FAX: (425) 455-0071  •  (800) 692-0200  •  www.aiphone.com

Accessories

RY-AC

EXTERNAL SIGNALING RELAY:

• Ring a standard doorbell or activate a separate device when a call is
   placed from a door station

-- LEF and LEF-C Series

• In high noise areas or where a light is needed, or to activate a bell, buzzer,
  or light when calling between handset-type intercoms

-- TD-H Series Selective Calling and Paging system
-- IE-8 Series Selective Calling Handset system

SPECIFICATIONS:

Power Source:

Supplied by master

Relay Switching Capacity:

1A @ 24V DC or 0.3A @ 240V AC
Normally open dry contact

Contact Closure:

Closed while call button is pressed

External Device Reqmnts:

AC or DC device not exceeding
contact capacity

Dimensions  (HxWxD):

4-1/16” x 2-1/4” x 1-3/8”

TAR-3

EXTERNAL SIGNALING RELAY:

• Ring a doorbell when a call is placed from a door station

-- IE-Series Handset systems
-- MY-1CD, MY-2CD and MK Video systems
-- K-Series Color Video systems

• Activate a light or a buzzer when a call is received

-- AT-406 Handset system
-- NEM Lamp Memory system
-- TB-M Internal Telephone system
-- IE-8 Selective Calling Handset system

SPECIFICATIONS:

Power Source:

6V DC, supplied by SKK-620

Relay Switching Capacity:

1A @ 24V DC or 0.3A @ 240V AC.
Normally open dry contact

Contact Closure:

Closed for the duration of the chime signal

External Device Reqmnts:

AC or DC device not exceeding
contact capacity

Dimensions  (HxWxD):

4-1/16” x 2-1/4” x 1-3/8”

- 78 -