8014493/ YDB5/2014-11-25
© SICK AG · Germany · All rights reserved · Subject to change without notice
Page 20 of 26
Bytes Parameter
index
LD-MRS parameter
datatype
Description
2
0x4002
StartAngle, Sector 2
INT16
In 1/32°, in the sensor
coordinate system.
Valid: 1600…-1919.
This is the start angle of
the second sector.
The angular resolution for this
sector is set with parameter
0x400A.
2
0x4003
StartAngle, Sector 3
INT16
…see above.
2
0x4004
StartAngle, Sector 4
INT16
…see above.
2
0x4005
StartAngle, Sector 5
INT16
…see above.
2
0x4006
StartAngle, Sector 6
INT16
…see above.
2
0x4007
StartAngle, Sector 7
INT16
…see above.
2
0x4008
StartAngle, Sector 8
INT16
…see above.
2
0x4009
Angular resolution,
Sector 1
INT16
Angular resolution of first
sector. Valid values are 32
(1.0°), 16 (0.5°), 8 (0.25°)
and 4 (0.125°).
2
0x400A
Angular resolution,
Sector 2
INT16
Angular resolution of
second sector.
2
0x400B
Angular resolution,
Sector 3
INT16
…see above.
2
0x400C
Angular resolution,
Sector 4
INT16
…see above.
2
0x400D
Angular resolution,
Sector 5
INT16
…see above.
2
0x400E
Angular resolution,
Sector 6
INT16
…see above.
2
0x400F
Angular resolution,
Sector 7
INT16
…see above.
2
0x4010
Angular resolution,
Sector 8
INT16