NOTE
Using an additional extension cable
•
If the serial interface (RS-232) is not being used, the maximum total length of
cable is 30 m.
•
If the serial interface (RS-232) is being used, the maximum total length of cable is
15 m.
•
Wire diameter: at least AWG26 (0.14 mm
2
).
Pin assignment
3
1
7
2
6
5
4
8
13
14
17
15
9
10
12
16
11
Figure 13: Male connector, M12, 17-pin, A-coded
Pin
Signal
Function
1
GND
Ground
2
V
S
Supply voltage
3
CAN L
CAN bus (IN/OUT)
4
CAN H
CAN bus (IN/OUT)
5
N.c.
Not connected
6
TxD (RS-232), host
Host interface (sender)
7
N.c.
Not connected
8
N.c.
Not connected
9
N.c.
Not connected
10
N.c.
Not connected
11
N.c.
Not connected
12
RxD (RS-232), host
Host interface (receiver)
13
N.c.
Not connected
14
N.c.
Not connected
15
N.c.
Not connected
16
N.c.
Not connected
17
N.c.
Not connected
–
–
Shield
6.4.2
Ethernet
Pin assignment
1
4
3
2
Figure 14: M12 female connector, 4-pin, D-coded
Pin
Signal
Function
1
TD+
6
ELECTRICAL INSTALLATION
30
O P E R A T I N G I N S T R U C T I O N S | GLS611
8026021/1D2S/2022-09-01 | SICK
Subject to change without notice