GLS611
Configuration
Image display
Diagnostics
SOPAS
SOPAS
Power / Serial Data /
CAN (Host)
Computer
Ethernet (AUX,
image transfer)
3
Ethernet
Ethernet
Cable
2
5
Cable
4
V
S
1
Figure 11: Connection block diagram for commissioning
1
Supply voltage V
S
2
Cable with open end
3
Ethernet, Aux interface (image transmission)
4
Adapter cable (male connector, M12, 4-pin, D-coded/male connector, RJ-45, 8-pin)
5
Configuration with SOPAS ET, image display or reading diagnostics
6.3.2
Connection principle for read mode
Ethernet (Host)
GLS611
Image display
SOPAS
SOPAS
Power / Serial Data /
CAN (Host)
HOST
Computer
Further data
processing
Ethernet (AUX
image transfer)
3
Ethernet
Ethernet
Cable
2
4
6
Reading result
5
V
S
1
Figure 12: Connection block diagram for read mode
1
Supply voltage V
S
2
Cable with open end
3
Ethernet, Aux interface (image transmission)
4
Image display
5
Read result
6
Data further processing
6.4
Pin assignments of electrical connections
6.4.1
Power/Serial Data/CAN
Important information
NOTE
Limitations in the options for backing up the parameter set
The device does not come with an AUX serial interface.
A current and application-specific parameter set created in SOPAS ET can therefore only
be
manually
saved and archived as a project file on the computer.
ELECTRICAL INSTALLATION
6
8026021/1D2S/2022-09-01 | SICK
O P E R A T I N G I N S T R U C T I O N S | GLS611
29
Subject to change without notice