9.3
Operation Startup of DME4000 PROFIBUS (Example: Siemens
Step 7)
The example results in the PROFIBUS profile setting recommended in the Appendix. Also refer to the
illustration (screen shot).
Step
Activity
Chapter
Step
Activity
Chapter
1
Connect and insert 8-pin sensor plug
2
Insert 4-pin PROFIBUS “Bus in” plug
3
Insert 4-pin PROFIBUS “Bus out” plug,
or insert terminal resistance
4
Set PROFIBUS address (default 006)
(menu item 3.1.2)
Select SICK
5
Set profile SICK (default)/Encoder
(menu item 3.1.1)
9/(Appendix: PROFIBUS
Interface)
6
Copy the GSD file SICK069D.gsd into the gsd directory
(:\siemes\step7\s7data\gsd)
Siemens
7
Update hardware catalog
Siemens
8
DME4000 PROFIBUS in hardware catalog
PROFIBUS-DP\additional field sensors\encoder\
DME4000 PROFIBUS
9
Install DME4000 on DP master system and assign
PROFIBUS address (cf. Step 4)
Select Class 2
10
Selection - Universal module
- Class 1: 4 byte input
- Class 2: 4 byte I/O
11
Assign output and input addresses
12
Parameterize
Siemens
Select
disabled
13
Extended diagnostics
Enabled: Send sensor specific diagnostic data
Disabled: Do not send sensor specific diagnostic data
Appendix: PROFIBUS Interface
14
Preset mode
Appendix: Preset
15
Profile selection
Appendix: PROFIBUS Interface
16
Plausibility
See 3 – Menu Structure: 3.7
17
Serial Mode: baud rate
See 3 – Menu Structure: 3.2
18
Serial Mode: parity
19
Measuring resolution (
µ
m)
See 3 – Menu Structure: 3.5
20
Offset (steps corresponding to resolution)
See 3 – Menu Structure: 3.6
21
Service MF1: Plausibility
See 3 – Menu Structure: 3.7
22
Service MF1: Ready
23
Service MF1: Laser
24
Service MF1: Level
26
Service MF1: LowerTemperature
27
Service MF1: UpperTemperature
28
Service MF2: Plausibility
See 3 – Menu Structure: 3.4.4
29
Service MF2: Ready
30
Service MF2: Laser
31
Service MF2: Level
32
Service MF2: Bus Status
33
Service MF2: LowerTemperature
34