Chapter
6
Operating Instructions
DME4000
100
© SICK AG • Germany • Subject to change without notice
8014584/ZN33/2017-07
Specifications
6.4
Specifications DME4000-1xx
DME4000-
111
112
113
114
115
117
119
Part no.
1029789 1029788 1029796 1029800 1029801 1029807 1042838
Measurement range
0.15 … 50 mm
Accuracy
±
3 mm
Reproducibility
1)
1 mm
Measurement value output
1 ms
2 ms
2 ms
2 ms
2 ms
2 ms
4 ms
Resolution (adjustable)
0.05 … 5 mm
Temperature drift (type)
0.1 mm/K
Temperature influence
1 ppm/K
Air pressure influence
0.3 ppm/hPa
Initialization time
500 ms
900 ms
500 ms
Max. movement speed
10 m/s
Supply voltage V
S
2)
18 … 30 V DC
Residual ripple
3)
5 V
PP
Current consumption (without
heating)
<
250 mA at 24 V DC
Optical transmitter
Laser diode (red light)
Laser class
2 (EN 60825-1/C.D.R.H.)
Operating life (at 25
°
C)
MTTF 50,000 h
Light spot diameter/distance
max. 100 mm/50 m
Switching outputs MF1, MF2
B (push/pull)
Output (MF1/MF2)
HIGH: V
S
<
3 V; LOW
<
2 V
Input (MF1)
4)
HIGH:
>
12 V; LOW
<
3 V
Output current
5)
100 mA (short-circuit protected, overload-protected)
Interfaces
SSI
PROFIBUS
12 MBd
RS 422
DeviceNet 500 kBd
Hiperface CANopen
Ambient operating temperature –10 … +55
°
C
Storage temperature
–25 … +75
°
C
DME4000 heating
121
122
123
124
Not
available
127
Part no.
1029792 1029793 1029797 1029808
1029812
Ambient operating temperature –40 … +55
°
C
Current consumption
(with heating)
<
1000 mA
Enclosure rating
IP 65
Electric protection class
VDE class 2 (rated voltage 32 V)
EMC
EN 61000-6-2, EN 55011: class B
Mechanical load
Shock: EN 600 68-2-27/-2-29, Sinus: EN 600 68-2-6, noise: EN 600 68-2-64
Weight
Approx. 1650 g
1)
Statistical error, constant ambient conditions, minimum switch-on time 10 min
2)
Reverse-polarity protected
3)
May not exceed or fall short of V
S
tolerances
4)
Not reverse-polarity protected
5)
Max. 100 nF/20 mH