When the restart interlock is configured, the application diagnostic output signals when
the reset pushbutton needs to be pressed. The application diagnostic output signals
“Reset required” and periodically switches between status HIGH and LOW so that any
suitable lamp that is connected flashes.
The device must be reset to the factory settings to deactivate the restart interlock.
Further topics
•
•
7.8
Configuring application diagnostic output
Overview
The application diagnostic output is configured automatically:
The following signals are output via the application diagnostic output depending on the
configured functions:
•
Reset required
•
Muting status
•
Override required
Reset required
When the protective device is free again after an interruption, the application diagnostic
output signals that the reset pushbutton needs to be pressed.
The application diagnostic output signals that reset is required and periodically
switches between HIGH and LOW so that any suitable lamp that is connected flashes.
Muting status
If the ESPE is in muting status (the protection of the ESPE is temporarily bypassed), the
application diagnostic output emits a constant signal.
Override required
If an error occurs during a valid muting condition, the ESPE makes a mandatory change
to the override status. The application diagnostic output signals this state with a peri‐
odic change between HIGH and LOW states.
CONFIGURATION
7
8024802/2020-07-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 LT Muting A/P
63