7
Configuration
7.1
Overview
Table 13: Functions and their configuration type
Function
Configuration type
Restart interlock
Automated configuration
Application diagnostic output (ADO)
C1 muting release
Muting
Wiring
Beam coding
Configuration information
b
Muting and beam coding are only applied in the system configuration if the device
contains a factory-set standard configuration (after delivery or after resetting the
configuration) and at least one muting arm is connected to the active unit.
b
If the device contains a factory-set standard configuration (after delivery or after
resetting the configuration) and no muting arm is detected when it is switched on,
the device indicates a configuration error.
b
If, after being switched on, the muting and beam coding configuration is different
from the system configuration, a configuration error is reported.
b
The device must be reset to the factory settings to change the muting or the beam
coding configuration.
b
Then ensure the correct functioning of the device.
7.2
Factory settings
Table 14: Configurable functions when delivered
Function
Configuration when delivered
Beam coding
Not configured
Restart interlock
Not configured
C1 muting release
Not configured
Muting
Not configured
Complementary information
The device must be reset to the factory settings to change the configuration to the fol‐
lowing functions:
•
Restart interlock
•
Beam coding
•
Muting
•
C1 muting release
Further topics
•
"Set to factory settings", page 59
7.2.1
Set to factory settings
Overview
To reset the functions to the factory settings, disconnect the muting arms from the
active unit.
CONFIGURATION
7
8024802/2020-07-17 | SICK
O P E R A T I N G I N S T R U C T I O N S | deTem4 LT Muting A/P
59