![SICK 6068088 Operating Instructions Manual Download Page 24](http://html.mh-extra.com/html/sick/6068088/6068088_operating-instructions-manual_1264185024.webp)
Index No.
Function
Further
description
R/W
Length
(bytes)
Contents/Meaning
0xnn98
Sensitivity
R/W
2
0: Auto adjust
1: Min Sense
2: 2nd Sense
3: 3rd Sense
4: 4th Sense
5: 5th Sense
6: Max Sense
0xnn99
Light threshold
R/W
2
0: Lowest
1: Lower
2: Middle
3: Upper
0xnn9B
Key lock active
R/W
2
0: Display active when locked
1: display inactive when locked
0xnnC8
Store zero-reset
W
2
0xnnC9
Cancel zero-reset
W
2
0xnnCA
Teach-in far
W
2
0xnnCB
Teach-in near
W
2
0xnnCC
Teach-in ObSB
W
2
0xnnD2
Reset
W
2
3: Execute
0xnnD3
Return to Top
Menu
W
2
Write any value to go back to Top Menu
0xnnD4
Factory reset
W
2
3: Execute
Module OL1 (on one channel of AOD1 evaluation unit)
0xnn00
Products series
b15-12 Manufacturer
b11-8 Categories
b7-0 Family
R
2
0x1321
1: SICK
3: Displacement
21: OL1
0xnn01
Product type
R
2
17
0xnn02
Firmware version
R
2
0x1011
0xnn03
Protocol version
R
2
0
0xnn04
Product Revision
R
2
0
0xnn05
Vendor name
R
2 ... 16
"SICK AG"
0xnn06
Product name
R
2 ... 32
Actual product type name
0xnn07
Product ID
R
2 ... 16
Actual product type code
0xnn08
User Tag name
R/W
2 ... 32
Blank space (default)
0xnn09
Operation Status
R
2
0: Init
1: Teach
2: Run
3: In operation by user
0xnn0E
Serial Number
R
16
Actual product serial number
AOD1 parameters (applied to both connected sensors)
0xnn64
Threshold
Near
R/W
2
-32768 ... 32767 (default: -50)
0xnn65
Far
R/W
2
-32768 ... 32767 (default: 50)
0xnn66
Output hysteresis
R/W
2
0 ... 32767 (default: 10)
0xnn6B
Monitor accumu‐
lations
R/W
2
Fieldbus channel #2 data selection
(0: Head2, 1: Accumulated value)
7
OPERATION
24
O P E R A T I N G I N S T R U C T I O N | WI180C-PN
8023551/11HP/2019-03-07 | SICK
Subject to change without notice