![SICK 6068088 Operating Instructions Manual Download Page 20](http://html.mh-extra.com/html/sick/6068088/6068088_operating-instructions-manual_1264185020.webp)
Index No.
Function
Further
description
R/W
Length
(bytes)
Contents/Meaning
0xnn64
Display
R/W
2
0: numeric display
1: bar display
2: percent display
0xnn66
Teach-in mode
CH1
R/W
2
0: 1-Point
1: 2-Point
2: Auto
3: Zone
4: Glass
0xnn67
CH2
2
0xnn68
Response speed
R/W
2
0: 16 us
1: 70 us
2: 250 us
3: 2 ms
4: 8 ms
0xnn69
Sender power
R/W
2
0: Low power
1: Middle power
2: Normal
0xnn6A
MF input
R/W
2
0: External teach-in
1: Test input
2: Synchronization
3: Counter reset
4: Master teach-in
5: No function
0xnn6B
Key lock
R/W
2
0: Cancel
1: Full-Lock
2: Lock but the external teach is available
0xnn6C
Operation mode
CH1
R/W
2
0: Light on
1: Dark on
0xnn6D
CH2
2
0xnn6E
Threshold level
CH1 Lower limit
R/W
2
"-999 ... 9999 Any value out of range will be
replaced by the nearest valid value."
0xnn6F
CH1 Upper limit
2
0xnn70
CH2 Lower limit
2
0xnn71
CH2 Upper limit
2
0xnn72
Timer setting
CH1
R/W
2
0: Off delay
1: One shot
0xnn73
CH2
2
0xnn74
Off delay time
CH1
R/W
2
"0 ... 9999: 0 ... 9999 ms
-1 … -9: 0.1 ... 0.9 ms"
0xnn75
On delay time
CH1
2
0xnn76
Off delay time
CH2
2
0xnn77
On delay time
CH2
2
0xnn7B
Hysteresis
R/W
2
1 ... 40
0xnn7D
ASC
R/W
2
0: off
1: normal
0xnn7E
Eco mode
R/W
2
0: off
1: energy saving display
0xnn7F
Reverse display
R/W
2
0: normal
1: display upside-down
0xnnC8
Store zero-reset
W
2
Write any value to execute Zero-reset
0xnnC9
Cancel zero-reset
W
2
Write any value to execute Zero-reset
0xnnCA
Teach-in 1-point
W
2
1: CH1
2: CH2
7
OPERATION
20
O P E R A T I N G I N S T R U C T I O N | WI180C-PN
8023551/11HP/2019-03-07 | SICK
Subject to change without notice