![SICK 6068088 Operating Instructions Manual Download Page 19](http://html.mh-extra.com/html/sick/6068088/6068088_operating-instructions-manual_1264185019.webp)
Index No.
Function
Further
description
R/W
Length
(bytes)
Contents/Meaning
0x2002
Firmware version
R
2
1
0x2003
Protocol version
R
2
1
0x2004
Product revision
R
2
1
0x2005
Vendor name
R
2 ... 16
"SICK AG"
0x2006
Product name
R
2 ... 32
"WI180C-PN"
0x2007
Product ID
R
2 ... 16
0x1300
0x2008
User Tag name
R/W
2 ... 32
Blank space
0x2009
Operation status
R
2
0: Idle
2: Run
0x200A
Vendor ID
R
2
257
0x200B
Network Profile
R
2 ... 32
"Profinet Coupler"
0x205F
Product serial
number
R
16
0x2061
Number of sen‐
sors
R
2
0 ... 16
0x2062
Error code
R/W
2
Read: last error code
Write any value: delete last error code
0x20C8
Firmware identi‐
fier application
R
4
0x20C9
Firmware identi‐
fier communica‐
tion
R
2 ... 16
0x20CA
Find me
R/W
2
0: Stop
1: Start
0x20D4
Factory reset
R
2
3: Execute
Module WLL180T
0xnn00
Products series
b15-12 Manufacturer
b11-8 Categories
b7-0 Family
R
2
0x1101 (1 output model)
0x1102 (2 outputs model)
1: SICK
1: Fiber amplifier
1: WLL180T 1 output
2: WLL180T 2 outputs
0xnn01
Product type
R
2
17: WLL180T
0xnn02
Firmware version
R
2
0x0200 or higher
0xnn03
Protocol version
R
2
1
0xnn04
Product Revision
R
2
1
0xnn05
Vendor name
R
2 ... 16
"SICK AG"
0xnn06
Product name
R
2 ... 32
Actual product type name
0xnn07
Product ID
R
2 ... 16
Actual product type code
0xnn08
User Tag name
R/W
2 ... 32
Blank space (default)
0xnn09
Operation Status
R
2
0: Init
1: Idle
2: Run
3: In operation by user
0xnn62
Error code
R/W
2
Read: last error code
Write any value: delete last error code
OPERATION
7
8023551/11HP/2019-03-07 | SICK
O P E R A T I N G I N S T R U C T I O N | WI180C-PN
19
Subject to change without notice