Figure 2-18: Upgrade window
In the StandBy SW area two buttons are available:
Activate:
by pressing this button a soft system restart is initiated loading as
ActiveSW
the
StandBySW
load available as back-up. At the end of the restart the old
StandBySW
becomes
ActiveSW
and the old
ActiveSW
is stored as back-up. In the case the new SW
does not operate correctly and generates continuous restarts, after five restarts the system
is automatically switched back to the stand-by bank and operates with the previous SW
release.
Download:
a new SW load can be retrieved from a network server on the system and
transferred to the FTP server running on the system. The new SW load is stored as
StandBySW.
At the end of the download, the new SW stored in the StandBy bank is
automatically activated. In the case the new SW does not operate correctly and generates
continuous restarts, after five restarts the system is automatically switched back to the
stand-by bank and operates with the previous SW release.
The download procedure is as follows:
o
Pressing the button the “SW Download” pop-up window (Fig. 2.19) opens
o
In the “SW Download” pop-up window click on “Select
File”
and write the path
where the file to be downloaded is located in the PC.
o
check that in the window the correct path is displayed
o
click on the button
“Upgrade”
in the window to start the file download
o
When the transfer is completed, the info about the
StandBySW
is updated.
o
In case of a correct transfer cannot be completed an error message is displayed
o
A switch between the
StandBy
and
Active
bank is automatically executed
o
The info about
ActiveSW
and
StandBySW
are updated in the Upgrade window
During the download of new software the system is operating normally and the traffic is not
affected. A short traffic interruption happens during the bank switch with restart.