Which can be used at the installation to connect each equipment from the CT (either LCT or RCT).
Before any other action, after having opened a session (see par 2.4), the IP addressing has to be
modified assigning the unique IP address defined by the customer according to the network
addressing plan. This can be done using the “System Settings/Management Interface” window
(see par. 2.10).
The IP address loaded during this session has to be used to control the equipment until modified
using the same procedure.
2.4.
Getting the Connection and setting Date and Time
Before opening any session as CT, the LAN port of the PC used as CT has to be assigned an IP
Address belonging to the same Subnet defined for the equipment.
The user can set up the required IP configuration by means of the following procedure:
1. Open “Network Connections” in the Control Panel of the PC
2. Select “LAN Connection” and with the right button of the mouse open the window
3. Click on “Properties”
4. In the window “General” select “Internet Protocol” and open “Properties”
5. Enter the IP address consistent with the Subnet of the equipment
6. Close (OK) the transaction
To open a session as LCT or RCT, the main window of the CT web interface can be get using a
standard browser and writing the Terminal IP address in the “Address” field:
1. Open the Browser (e.g. Internet Explorer)
2. Enter the IP Address of the Terminal as defined at installation or previously assigned (see
par. 2.3) and open the connection.
3. Enter Username and Password in the pop-up login window which opens (Fig. 2.2).
Figure 2-1: Login Window
The Username has the default value “operator” which cannot be changed.
The default value for the Password is “o”. The Password can be changed by the operator through
the procedure detailed in par. 2.17.2)
If another user is already logged, instead of the Login window the pop-up window of Fig. 2.3-a will
be opened and the user cannot login.