Important Note:
To assure the correct interworking of the ODU and Indoor card, the MAC
Address of the indoor card (either PSE/w or PSE/L depending on the configuration) must be defined
at the system start up. In case of replacement (e.g. repair, etc.) the MAC address must be updated:
- Automatically, setting the
IDU MAC Autodiscovery
field to “Enabled” and clicking on the
<Apply> button. A SW procedure is started which uploads the IDU MAC Address, which is
then displayed in the
IDU MAC Address
field.
- Manually, entering the new MAC Address in the
IDU MAC
field and clicking on the <Apply>
button. The MAC Address to be entered can be read from the label on the case of the indoor
unit
If the PSE MAC address is not configured or incorrect, the indoor unit cannot be reached and its
functions are not supported.
System Identity:
the parameters identifying the system are displayed and can be entered
in the relevant fields and modified by this window. The same information is also displayed
in the
Settings
area of the System Status window.
The Link Identity (unique within the same network) is used for administration purposes (e.g.
on an OS). The following rules must be met:
o
The two terminals of a 1+0 link must have the same Link Identity
o
The four terminals of a 1+1 HSB link must have the same Link Identity
The Encryption Key (0-255) is used to cipher the radio bitstream. If the field is left empty
(default), no ciphering is performed. The following rules must be met:
o
The two terminals of a 1+0 link must have the same Encryption Key
o
The four terminals of a 1+1 HSB link must have the same Encryption Key
New parameters are activated only when the <Apply> button at the bottom of the area is
pressed
System Time:
this area allows to manage information related to system time and sources
to be used to synchronize it. The System Date can be set up by manual resynchronization
with the CT or NTP server after setting the appropriate fields in the window by pressing the
<Apply> button at the bottom of the area.
Note:
System Date information is not maintained at power shut down. After the equipment is again
powered up, an automatic synchronization with the NTP server is performed and if successful
realign Time and Date. Automatic resynchronization with the defined NTP is also performed every
30 minutes.
Management Interface:
this area is dedicated to enter and manage information related to
Management Interface and its addressing. New parameters are activated only when the
<Apply> button at the bottom of the area is pressed
System Restart:
an <Apply> button is available to execute a SW restart of the equipment
on operator’s command. After pressing the button, the pop-window of Fig. 2.2 appears and
the operator must reenter UserName and Password.