![Sicam SBM 55 NW Original Instructions Manual Download Page 38](http://html1.mh-extra.com/html/sicam/sbm-55-nw/sbm-55-nw_original-instructions-manual_1263671038.webp)
1 695 656 076
2012-03-28
|
Sicam srl società unipersonale
38 | SBM 55 NW | Commissioning
en
4.6
Calibration of SBM 55 NW
!
Calibration must be performed after initial commis-
sioning.
1.
Flange calibration.
2.
SBM 55 NW calibration.
3.
Perform reference measurement.
i
Calibration is described in Section 12.3
4.5
Checking the direction of rotation
1.
Check that the SBM 55 NW is correctly connected to
the mains power supply.
2.
Switch on the SBM 55 NW with the On/Off switch.
i
After the SBM 55 NW is switched on, the software
version appears in the control/display panel for
several seconds. After this, both displays show the
value
0
.
3.
Close the wheel protection cap.
The shaft rotates.
i
If the shaft does not turn, press the <
START
> key
4.
Check the direction of rotation of the shaft.
i
The correct direction of rotation is indicated by an ad-
hesive on the right side of the SBM 55 NW (chap.1.2.1).
i
If the direction of rotation is incorrect, the
SBM 55 NW comes to an immediate stop and dis-
plays the error message
ERR 3
(
see section 11).