background image

 
 
 
 
 

 

 
 
 
 
 

Aqua Cubic Multiplex

 - 

MAN0004 Rev. B  29.03.99                                                                                                                       

25/33 

 

 

Tab. 25 – Table of the programming codes  

Code 

visualised  

 

Display

 

Meaning

 

P 0 0 2 

ENTER 

 

Modifies the

 movement times

 of all of the phases of the regeneration 

taking them to 

5 seconds

. May be used to carry out trial regenerations. To 

reset the correct times, the programming of the flags must be run through. 

 

Cannot be used for trials with the hydraulic distributors. 

 

P 0 1 0 

ENTER 

d H x x 

Programming

 

of the

 hardness value

. May have values from 

1

 to 

99

At the end of the programming calculates the mew volume values, which 
become active immediately if the 

2CP 

is programmed to 

0

, otherwise, will 

become active after the first regeneration or the reset of the appliance using 
the code 

220

The hardness value must be expressed in 

French degrees. 

 

P 0 1 1 

ENTER 

C h x.x 

Programming of the 

value of capacity of resins exchange; xx

 may go 

from 

1.4

 to 

9.0

, and is expressed in terms of gr CaCO

3

/litre resin. 

ENTER 

x x x x 

Regeneration time; 

to change the flashing digit, use the 

2/+

, press 

PROGRAM

 to go from the minutes to the hours. 

P - x x 

Days of interval 

between two regenerations 

(from 1 to 30)

 

P 0 1 2 

PROGRAM 

1 P P x 

Active days.

 If the flag 

1HP

 is programmed with the value 

1

, instead of 

the interval days, the days of the week on which the regeneration is to be 
carried out are programmed.  

ENTER 

x x x x 

Programming of the 

local 

time.  

P 0 2 0 

PROGRAM 

P - - x 

Programming of the 

day 

of the 

week: 

x may be 1=Monday, 2=Tuesday, 

3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday, 7=Sunday 

ENTER 

x x x x 

Programming of the 

volume of the resin

 (in litres) of the column 

A: 

may 

go from 

to 

10000

 ( to have 10000 litres, programme 

0000

PROGRAM 

H H x x 

Programming of the 

percentage of reserve 

of the column

 A

; the value of 

the reserve may go from 10% to 80% of the total volume. 

P 1 0 0 

PROGRAM 

A A 0 5 

Tollerance on the capacity of the tank. The value 

00

 is recommended. 

ENTER 

x x x x 

Programming of the 

volume of the resin

 (in litres) of the column 

B: 

may 

go from 

to 

10000

 ( to have 10000 litres, programme 

0000 

PROGRAM 

H H x x 

Programming of the 

percentage of reserve 

of the column

 B

; the value of 

the reserve may go from 10% to 80% of the total volume. 

P 1 0 1 

PROGRAM 

A A 0 5 

Tolerance on the capacity of the tank. The value 

00

 is recommended. 

ENTER 

x x x x 

Programming of the 

volume of the resin

 (in litres) of the column 

C: 

may 

go from 

to 

10000

 ( to have 10000 litres, programme 

0000

PROGRAM 

H H x x 

Programming of the 

percentage of reserve 

of the column

 C

; the value of 

the reserve may go from 10% to 80% of the total volume. 

P 1 0 2 

PROGRAM 

A A 0 5 

Tolerance on the capacity of the tank. The value 

00

 is recommended 

P 1 1 0 

ENTER 

x x x x 

Programming of the 

ratio impulses/litre

 (prescaler) of the counter.  

If the flag 

0CP 

is at 

0

, the divider is free and the value may go from 

0

 to 

899 

impulses / litre. If 

0CP 

is at 

1

 the divider is pre-programmed; see par 

6.6 for the list of the available options.  

ENTER 

1 C x x 

Programming of the 

 stop times 

, in minutes, of the 

regeneration cycle

 of 

the column 

B; xx 

varies from 

1

 to 

99

 minutes

 

 

P 1 1 1 

PROGRAM 

* C x x 

*

 stands for the phases 2, 3 and 4 of the regeneration cycle of the column 

B

 
 

Summary of Contents for AQUA CUBIC MULTIPLEX

Page 1: ...Aqua Cubic Multiplex MAN0004 Rev B 29 03 99 1 33 USE AND MAINTENANCE MANUAL AQUA CUBIC MULTIPLEX...

Page 2: ...tic Compatibility 89 336 CEE 93 68 CEE Low Voltage 73 23 CEE 93 68 CEE The fulfilment of the following regulations has been verified EN 50081 1 General Regulation on Emissions part 1 residential comme...

Page 3: ...amming of the flags 14 6 2 2 c List of codes to be programmed 15 6 2 3 PPP2 Two alternated single columns 15 6 2 3 a Operative characteristics 15 6 2 3 b Programming of the flags 17 6 2 3 c List of co...

Page 4: ...ifying the programming during service the flag 2CP 30 7 What to do if 30 7 1 Aqua Cubic Multiplex does not come on 30 7 2 the motors of the distributors do not stop 30 7 3 there is no current to the u...

Page 5: ...l characteristics to be controlled that is with different volume values also allowing the differentiation of the regeneration cycle times The regeneration cycle is completely programmable it can be st...

Page 6: ...oltage 230 Vac 10 Network frequency 50 Hz 3 Power absorbed 30 VA Operative temperature 0 C 55 C Class of protection IP65 Protection from disturbances ICE 65 Trial class 4 3000 V Reading scale 0 999 99...

Page 7: ...e programming code When the flag 1dP is programmed to 1 starts up the regeneration of the column visualised by the display During a stop phase of the regeneration cycle annuls the residual time and ac...

Page 8: ...red by a certificate with the IP65 grade of protection Aqua Cubic Multiplex is therefore protected against infiltration of dust and direct jets of water This protection is valid when the cover is clos...

Page 9: ...be carried out via the keypad on the front of the appliance Aqua Cubic Multiplex Plus has the following operative modalities Tab 4 Table of the operative modalities Code Description Rotation times P...

Page 10: ...rt active for 15 seconds 0 0 0 0 The reg does not start The reg does not start Immediate start Immediate start 0 0 0 1 The reg does not start The reg does not start Immediate start Immediate start 0 0...

Page 11: ...e 2 0 H P 0 H P 1 Regeneration at the programmed time and deferred to the time by finished volume PROGRAM 1 H P 1 H P 0 The interval days between two regenerations are programmed 2 1 H P 1 H P 1 The a...

Page 12: ...inal board will be active respectively for the column A and the column B while the pins 47 48 for the column C will be inactive The LEDs A Service and B Service on the panel will be on while the LED C...

Page 13: ...tart Immediate start 1 Immediate start Not available 0 1 1 1 The reg does not start Immediate start 1 Immediate start Not available 1 0 0 0 The reg does not start Immediate start 1 Immediate start Not...

Page 14: ...1 Modality of the litre counter divider 1 pre programmed see par 6 6 PROGRAM 1 C P 1 C P 0 Same times of the regeneration cycle for the columns A C and B 2 1 C P 1 C P 1 Different times of the regene...

Page 15: ...ree alternated single columns PPP1 of different dimensions Code Meaning 011 Programming of the value of the capacity of resins exchange 020 Programming of the time and of the day of the week non influ...

Page 16: ...volume reaches the reserve The volume runs out Remote start active for 15 seconds 0 0 0 0 The reg does not start The reg does not start Immediate start The reg does not start 0 0 0 1 The reg does not...

Page 17: ...r 0 free see par 6 6 2 0 C P 0 C P 1 Modality of the litre counter divider 1 pre programmed see par 6 6 PROGRAM 1 C P 1 C P 0 Same times of the regeneration cycle for the columns A and B 2 1 C P 1 C P...

Page 18: ...mn A 010 Programming of the hardness value 220 Initialisation of the system Remember that in order to use Aqua Cubic Multiplex as described in tab 16 the flag 1CP must be programmed to 1 6 2 4 PPP4 On...

Page 19: ...vice This operative modality is not programmable As shown in tab 17 any programming of the flags always brings on the same result When one column finishes the available volume the controller immediate...

Page 20: ...d PROGRAM 0 C P 0 C P 0 Modality of the litre counter divider 0 free see par 6 6 2 0 C P 0 C P 1 Modality of the litre counter divider 1 pre programmed see par 6 6 PROGRAM 1 C P 1 C P 0 FLAG not used...

Page 21: ...columns are put into service The signals to the pins 43 44 and 45 46 of the terminal board will be active Both of the LEDs A Service and B Service on the panel will be on The LED A will be on to indic...

Page 22: ...t Immediate start The reg does not start 1 0 1 1 The reg does not start Imm start 1 Immediate start The reg does not start 1 1 0 0 The reg does not start The reg does not start Immediate start The reg...

Page 23: ...the new parameters 6 2 5 c List of codes to be programmed For the programming and the meaning of the codes see par 6 3 In this modality the programming of the following codes is recommended Tab 22 Ta...

Page 24: ...ppears in place of the x it should be understood that there are numbers which vary on the basis of the pressing of the keys Tab 24 Access to the programming codes Display Meaning PROGRAM P 0 0 0 Modal...

Page 25: ...day 4 Thursday 5 Friday 6 Saturday 7 Sunday ENTER x x x x Programming of the volume of the resin in litres of the column A may go from 1 to 10000 to have 10000 litres programme 0000 PROGRAM H H x x Pr...

Page 26: ...erve value This is programmed via the codes 100 101 and 102 respectively for columns A B and C and expresses the percentage of the total volume available which must be held in reserve Thus if there ar...

Page 27: ...s by one unit pre programmed prescaler if the flag 0CP is equal to 1 in this case the prescalers which can be used are those indicated in the first column of table 18 Tab 26 Table of the pre programme...

Page 28: ...at the cams of the distributors are on the position of stroke end except when they are in regeneration a condition which may be verified via the led Regen and that any unused limit switch entries are...

Page 29: ...he columns with the same times or with different times via the flag 1CP When it is programmed with the value 0 the columns regenerate with the same times those programmed for the column A with the cod...

Page 30: ...rogramme the flag 2CP with the value 1 at the end of the installation so that any modifications to the parameters during the service of Aqua Cubic Multiplex do not upset the possibility of the system...

Page 31: ...at the end of which it automatically returns into service The controller is programmed in the modality three alternated single columns PPP1 Whatever the problem is as long as it is limited to only on...

Page 32: ...Aqua Cubic Multiplex MAN0004 Rev B 29 03 99 32 33 Appendix A...

Page 33: ...Aqua Cubic Multiplex MAN0004 Rev B 29 03 99 33 33 Appendix B...

Reviews: