Aqua Cubic Multiplex
-
MAN0004 Rev. B 29.03.99
25/33
Tab. 25 – Table of the programming codes
Code
visualised
Display
Meaning
P 0 0 2
ENTER
Modifies the
movement times
of all of the phases of the regeneration
taking them to
5 seconds
. May be used to carry out trial regenerations. To
reset the correct times, the programming of the flags must be run through.
Cannot be used for trials with the hydraulic distributors.
P 0 1 0
ENTER
d H x x
Programming
of the
hardness value
. May have values from
1
to
99
.
At the end of the programming calculates the mew volume values, which
become active immediately if the
2CP
is programmed to
0
, otherwise, will
become active after the first regeneration or the reset of the appliance using
the code
220
.
The hardness value must be expressed in
French degrees.
P 0 1 1
ENTER
C h x.x
Programming of the
value of capacity of resins exchange; xx
may go
from
1.4
to
9.0
, and is expressed in terms of gr CaCO
3
/litre resin.
ENTER
x x x x
Regeneration time;
to change the flashing digit, use the
2/+
, press
PROGRAM
to go from the minutes to the hours.
P - x x
Days of interval
between two regenerations
(from 1 to 30)
P 0 1 2
PROGRAM
1 P P x
Active days.
If the flag
1HP
is programmed with the value
1
, instead of
the interval days, the days of the week on which the regeneration is to be
carried out are programmed.
ENTER
x x x x
Programming of the
local
time.
P 0 2 0
PROGRAM
P - - x
Programming of the
day
of the
week:
x may be 1=Monday, 2=Tuesday,
3=Wednesday, 4=Thursday, 5=Friday, 6=Saturday, 7=Sunday
ENTER
x x x x
Programming of the
volume of the resin
(in litres) of the column
A:
may
go from
1
to
10000
( to have 10000 litres, programme
0000
)
PROGRAM
H H x x
Programming of the
percentage of reserve
of the column
A
; the value of
the reserve may go from 10% to 80% of the total volume.
P 1 0 0
PROGRAM
A A 0 5
Tollerance on the capacity of the tank. The value
00
is recommended.
ENTER
x x x x
Programming of the
volume of the resin
(in litres) of the column
B:
may
go from
1
to
10000
( to have 10000 litres, programme
0000
)
PROGRAM
H H x x
Programming of the
percentage of reserve
of the column
B
; the value of
the reserve may go from 10% to 80% of the total volume.
P 1 0 1
PROGRAM
A A 0 5
Tolerance on the capacity of the tank. The value
00
is recommended.
ENTER
x x x x
Programming of the
volume of the resin
(in litres) of the column
C:
may
go from
1
to
10000
( to have 10000 litres, programme
0000
)
PROGRAM
H H x x
Programming of the
percentage of reserve
of the column
C
; the value of
the reserve may go from 10% to 80% of the total volume.
P 1 0 2
PROGRAM
A A 0 5
Tolerance on the capacity of the tank. The value
00
is recommended
P 1 1 0
ENTER
x x x x
Programming of the
ratio impulses/litre
(prescaler) of the counter.
If the flag
0CP
is at
0
, the divider is free and the value may go from
0
to
899
impulses / litre. If
0CP
is at
1
the divider is pre-programmed; see par
6.6 for the list of the available options.
ENTER
1 C x x
Programming of the
stop times
, in minutes, of the
regeneration cycle
of
the column
B; xx
varies from
1
to
99
minutes
P 1 1 1
PROGRAM
* C x x
*
stands for the phases 2, 3 and 4 of the regeneration cycle of the column
B