Aqua Cubic Multiplex
-
MAN0004 Rev. B 29.03.99
16/33
With the key
2/+
it is possible to change the column visualised on the display. Each time the key is pressed, the LEDs
A
or
B
will come on when the data of the relative column is transferred to the display. Se the column visualised is in
service the residual volume can be read. If it is in regeneration, the progression can be followed. If it is in stand-by, the
display will show four lines.
When the column in service goes into regeneration by finished volume, the column in stand-by will go into service in
place of the column which has just run out. The LEDs on the panel will come on to indicate a new situation. The LED
Regeneration
will be on for the whole duration of the regeneration cycle. The signals to the pins of the terminal board
shown above will also activate in line with the new situation.
This operative modality is not programmable. As may be seen in tab. 13, any programming of the flags always brings
on the same result.
When one column finishes the available volume, the controller immediately enters into regeneration, and the column in
stand-by enters into service. There is no control either on the reserve or on the remote start.
Tab. 13 – Consequences of the events on the working of the controller on the basis of the programming.
Events
Programming
0HP 1HP 2HP 0dP
The reg. time is set off
with the finished days.
The volume reaches
the reserve.
The volume runs
out.
Remote start active
for 15 seconds.
0 0 0 0
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
0
0
0
1
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
0 0 1 0
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
0
0
1
1
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
0 1 0 0
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
0
1
0
1
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
0 1 1 0
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
0
1
1
1
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
1 0 0 0
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
1
0
0
1
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
1 0 1 0
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
1
0
1
1
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
1 1 0 0
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
1
1
0
1
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
1 1 1 0
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.
1
1
1
1
The reg. does not start.
The reg. does not start.
Immediate start.
The reg. does not start.