Aqua Cubic Multiplex
-
MAN0004 Rev. B 29.03.99
23/33
2 / +
0 C P
0 C P 1
Modality of the litre counter divider (1 = pre-programmed see par. 6.6)
PROGRAM
1 C P
1 C P 0
Same times of the regeneration cycle for the two columns
A
and
B
2 / +
1 C P
1 C P 1
Different times of the regeneration cycle for the two columns
A
and
B
PROGRAM
2 C P
2 C P 0
The new programming is immediately operative.
2 / +
2 C P
2 C P 1
The new programming is operative after the next regeneration
PROGRAM
3 C P
3 C P 0
FLAG not used
PROGRAM
0 d P
0 d P 0
Disables the control of the reserve
PROGRAM
0 d P
0 d P 1
Enables the control of the reserve
PROGRAM
1 d P
1 d P 1
Enables the start and the stop of the
manual regeneration
with the keys
1
and
0
PROGRAM
2 d P
2 d P 0
FLAG not used
PROGRAM
3 d P
3 d P 0
FLAG not used
PROGRAM
The rapid
flashing
of the display indicates that the values have been saved in the
eeprom
At the end of the programming the code
220
must always be keyed in (see par. 6.3) to initialise
Aqua Cubic Multiplex
with the new parameters.
6.2.5.c – List of codes to be programmed
For the programming and the meaning of the codes see par. 6.3. In this modality, the programming of the following
codes is recommended:
Tab. 22 – Table of the codes recommended in the modality “two single columns in parallel, PPPA”
Code Meaning
011
Programming of the value of the capacity of resins exchange
100
Programming of the volume of resin and of the percentage of reserve of the column
A
110
Programming of the litre counter divider (prescaler)
112
Programming of the regeneration cycle ( stop times )
210
Transfer of the parameters programmed for column
A
on column
B
010
Programming of the hardness value
220
Initialisation of the system
If columns of different dimensions are used, the programming recommended varies as follows:
Tab. 23 – Table of the codes recommended in the modality “due single columns in parallel, PPPA” different
columns
Code Meaning
011
Programming value of the capacity of resins exchange
100
Programming of the volume of resin and of the percentage of reserve of the column
A
101
Programming of the volume of resin and of the percentage of reserve of the column
B
110
Programming of the litre counter divider (prescaler)