6.2.3.b – Programming of the flags
Tab. 14 shows the options available for the modality
PPP2
:
Tab. 14 – Selection of the operative modality “two alternated single columns, PPP2”
FLAG
Display
Operative state / Data visualised
PROGRAM
P 0 0 0
State of access to the selection of the operative modality
ENTER
P P P x
Visualisation of the current operative modality (x = 0, 1, 2, 4, A)
2 / +
P P P 2
The key
2 / +
modifies the operative modality as per tab. 4 : returns to2
PROGRAM
0 H P
0 H P 0
FLAG not used
PROGRAM
1 H P
1 H P 0
FLAG not used
PROGRAM
2 H P
2 H P 0
FLAG not used
PROGRAM
3 H P
3 H P 0
FLAG not used
PROGRAM
0 C P
0 C P 0
Modality of the litre counter divider (0 = free see par. 6.6)
2 / +
0 C P
0 C P 1
Modality of the litre counter divider (1 = pre-programmed see par. 6.6)
PROGRAM
1 C P
1 C P 0
Same times of the regeneration cycle for the columns
A
and
B
2 / +
1 C P
1 C P 1
Different times of the regeneration cycle for the columns
A
and
B
PROGRAM
2 C P
2 C P 0
The new programming is immediately operative.
2 / +
2 C P
2 C P 1
The new programming is operative after the next regeneration.
PROGRAM
3 C P
3 C P 0
FLAG not used
PROGRAM
0 d P
0 d P 0
FLAG not used
PROGRAM
1 d P
1 d P 1
Enables the start and stop of the
manual regeneration
with the keys
1
and
0
PROGRAM
2 d P
2 d P 0
FLAG not used
PROGRAM
3 d P
3 d P 0
FLAG not used
PROGRAM
The rapid
flashing
of the display indicates that the values have been saved in the
eeprom
At the end of the programming the code
220
must always be keyed in (see par. 6.3) to initialise
Aqua Cubic Multiplex
with the new parameters.