background image

DIS Digital Conference System 

User Manual

 

 

4

apparatus,  the  apparatus  has  been 
exposed  to  rain  or  moisture,  does  not 
operate normally, or has been dropped

18

 

Replacement  Parts

  -  When  replacement 

parts  are  required,  be  sure  the  service 
technician  has  used  replacement  parts 
specified  by  the  manufacturer  or  having  the 
same characteristics as the original part. 

Unauthorized substitutions may result in fire, 
electric shock or other hazards. 

19

 

Safety  Check

  -  Upon  completion  of  any 

service  or  repairs  to  this  apparatus,  ask  the 
service technician to perform safety checks to 
determine  that  the  apparatus  is  in  proper 
operating condition. 

20

 

Overloading

  -  Do  not  overload  outlets  and 

extension cords as this can result in a risk of 
fire or electric shock. 

21

 

Power  Sources

  -  This  apparatus  should  be 

operated only from the type of power source 
indicated on the marking label. If you are not 
sure of the type of power supply you plan to 
use,  consult  your  appliance  dealer  or  local 
power company. For apparatuses intended to 
operate from battery power, or other sources, 
refer to the operating instructions. 

22

 

Power Lines

 - An outdoor system should not 

be  located  in  the  vicinity  of  overhead  power 
lines or other electric light or power circuits, or 
where  it  can  fall  into  such  power  lines  or 
circuits.  When  installing  an  outdoor  system, 
extreme  care  should  be  taken  to  keep  from 
activating  such  power  lines  or  circuits,  as 
contact with them might be fatal.  

23

 

Object  and  Liquid  Entry

  -  Never  push 

objects of any kind into this apparatus through 
openings  as  they  may  touch  dangerous 
voltage  points  or  short-out  parts  that  could 
result in a fire or electric shock.  

Never spill liquid of any kind on the 
apparatus. Should any liquid or solid object 
fall into the cabinet, unplug the unit and have 
it checked by qualified personnel before 
operating it further. 

Labels  

“Lightning Flash Symbol” with 
the lightning flash with 
arrowhead symbol within an 
equilateral triangle, is intended 
to alert the user to the presence 
of un-insulated "dangerous 

voltage" within the product enclosure that may 
be of sufficient magnitude to constitute a risk of 
shock to persons. 

“Exclamation Point Symbol” with the 
exclamation point within an equilateral triangle 
is intended to alert the user to the presence of 
important operating and maintenance 
(servicing) instructions in the literature 
accompanying the product. 

Note for Power Connections 

Check that the voltage of your local 
power supply is within the 
operating voltage of the unit. If a 

voltage conversion is required, consult your DIS 
dealer or qualified personnel. 

Set the Power switch to ‘Off’ if it is not used for 
several days.  

Important:

 The equipment must be connected 

to earth (ground) 

The wires in the main lead supplied with the 
equipment are colored in accordance with the 
following codes: 

 

Green-and-yellow  Earth (Ground) 

 

Blue  

  Neutral 

 

Brown  

  Live 

The green-and-yellow wire must be connected 
to the terminal in the plug marked with the 
letter E or with the safety earth symbol or 
marked with green-and-yellow color.  

The blue wire must be connected to the 
terminal marked with the letter N or marked 
with black color.  

The brown wire must be connected to the 
terminal marked with the letter L or marked 
with red color.  

For pluggable equipment, the socket-outlet shall 
be installed near the equipment and shall be 
easily accessible. 

Power Disconnect 

Apparatuses with or without On/Off switches 
have power supplied to the apparatus whenever 
the power cord is inserted into the power 
source; however, the apparatus is operational 
only when the On/Off switch is in the On 
position. The power cord is the main power 
disconnect for all apparatuses. 

Compliancy 

Summary of Contents for EX 6010

Page 1: ...2015 Shure Incorporated User Manual EX 6010 rev I English docx Conferencing and Discussion Systems EX 6010 Extension Unit USER GUIDE...

Page 2: ...CS 6000 system 6 System components 7 Central equipment etc 7 Interpreter equipment 7 Conference units and Ch selectors 7 Accessories 7 General Description 8 Features 8 Operating instruction 9 User Con...

Page 3: ...ear any heat sources such as radiators heat registers stoves air ducts or other apparatus including amplifiers that produce heat 10 Do not install the unit in a place exposed to direct sunlight excess...

Page 4: ...into the cabinet unplug the unit and have it checked by qualified personnel before operating it further Labels Lightning Flash Symbol with the lightning flash with arrowhead symbol within an equilate...

Page 5: ...nterference in which case the user will be required to correct the interference at his own expense Intentional or unintentional changes or modifications not expressly approved by the party responsible...

Page 6: ...nel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system Delegate and Interpreter units are powered and controlled by the CU 61xx Central Unit w...

Page 7: ...nference Unit portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DM 6620 F Conference Unit flush mounted with Chip card and 5 voting buttons CM DM 6680 F C...

Page 8: ...h are built into a 19 cabinet Repeater splitter board with 4 individual outputs 4 individual power supplies Features The main features of the EX 6010 Extension Unit are Built in Power Supplies for app...

Page 9: ...es when power is switched ON 2 Fault LED This indication lights up if the internal power supply is malfunctioning i e because of overheating or overload of a chain The Fault LED will always light up s...

Page 10: ...EX 6010 5 Repeated Chains 1 2 3 4 RJ45 connector 4 pieces Those connectors are DCS LAN connectors for connection to DM CM 6xxx IS 6132 CS 6032 EX 6010 AO 6004 6008 etc 6 Power LED s Those LED s light...

Page 11: ...reter sets for those languages have to be connected either to another EX 6010 Extension Unit which is connected to another of the four chains on the CU 6110 or directly to one other of the four chains...

Page 12: ...unlimited number of EX 6010 can be connected by using the Loop through connector However the practical limitation is the maximum cable length in one chain which is 200 m and the supply of power to th...

Page 13: ...feeding cable and the length of the cable between each unit If the feeding cables are short and the cables between the units are short more units can be connected than if the feeding cable is long an...

Page 14: ...th of Feeding Cable Type CAT5e AWG24 Length of inter connecting Cable Type CAT5e AWG24 Total cable length Max number of DC 6990 P pr output 10 m 1 m 35 m 26 30 m 1 m 53 m 24 50 m 1 m 70 m 21 100 m 1 m...

Page 15: ...terpreter Units connected The numbers are with no loudspeakers connected Note The number of units is dependent of how many interpreter sets there are per booth or language as there only can be one set...

Page 16: ...DCS 6000 Digital Conference System User Manual 16 Typical schematics The following schematics are showing a typical configuration with use of EX 6010 Figure 0 A System with EX 6010...

Page 17: ...2 pieces RJ45 DCS LAN repeated output 4 pieces RJ45 Cabling and System Limits Cable type min specification Cat5e AWG 24 shielded Maximum cable length in one chain 200 m System Environmental Conditions...

Page 18: ...BLU 5 0V BLU WHT BLU WHT 6 48V GRN GRN 7 Outgoing BRN WHT BRN WHT 8 Outgoing BRN BRN Important If other color codes are used then the four pairs are connected as follows Pair 2 Pin 1 2 Pair 3 Pin 3 6...

Page 19: ...1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email inf...

Reviews: