background image

DCS 6000  Digital Conference System 

User Manual

 

 

9

 

Operating instruction 

User Controls, indications & connectors 

Front plate layout  

 

Front plate controls 

The EX 6010 Extension Unit features the following 
controls and display: 

1.

 

Power Led 

When power is switched ON at the CU 6105 or CU 
6110 Central Unit any connected EX 6010 
Extension Units will automatically be powered up. 
An LED indicates when power is switched ON. 

2.

 

Fault LED 

This indication lights up, if the internal power 
supply is malfunctioning i.e. because of 
overheating or overload of a chain.  

The Fault LED will always light up some seconds 
after the unit is switched on caused by the 
delayed switching on of the four supplies. 

As a warning the light is flashing at an internal 
temperature above 45

°

C. At a temperature 

above 55

°

C or if one of the DCS-LAN outputs is 

supplying no voltage, the LED is lighting 
constantly. 

Please note that the maximum ambient 
temperature for the CU 6105 or CU 6110 is 40 
deg. Celsius. 

 

 

Summary of Contents for EX 6010

Page 1: ...2015 Shure Incorporated User Manual EX 6010 rev I English docx Conferencing and Discussion Systems EX 6010 Extension Unit USER GUIDE...

Page 2: ...CS 6000 system 6 System components 7 Central equipment etc 7 Interpreter equipment 7 Conference units and Ch selectors 7 Accessories 7 General Description 8 Features 8 Operating instruction 9 User Con...

Page 3: ...ear any heat sources such as radiators heat registers stoves air ducts or other apparatus including amplifiers that produce heat 10 Do not install the unit in a place exposed to direct sunlight excess...

Page 4: ...into the cabinet unplug the unit and have it checked by qualified personnel before operating it further Labels Lightning Flash Symbol with the lightning flash with arrowhead symbol within an equilate...

Page 5: ...nterference in which case the user will be required to correct the interference at his own expense Intentional or unintentional changes or modifications not expressly approved by the party responsible...

Page 6: ...nel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system Delegate and Interpreter units are powered and controlled by the CU 61xx Central Unit w...

Page 7: ...nference Unit portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DM 6620 F Conference Unit flush mounted with Chip card and 5 voting buttons CM DM 6680 F C...

Page 8: ...h are built into a 19 cabinet Repeater splitter board with 4 individual outputs 4 individual power supplies Features The main features of the EX 6010 Extension Unit are Built in Power Supplies for app...

Page 9: ...es when power is switched ON 2 Fault LED This indication lights up if the internal power supply is malfunctioning i e because of overheating or overload of a chain The Fault LED will always light up s...

Page 10: ...EX 6010 5 Repeated Chains 1 2 3 4 RJ45 connector 4 pieces Those connectors are DCS LAN connectors for connection to DM CM 6xxx IS 6132 CS 6032 EX 6010 AO 6004 6008 etc 6 Power LED s Those LED s light...

Page 11: ...reter sets for those languages have to be connected either to another EX 6010 Extension Unit which is connected to another of the four chains on the CU 6110 or directly to one other of the four chains...

Page 12: ...unlimited number of EX 6010 can be connected by using the Loop through connector However the practical limitation is the maximum cable length in one chain which is 200 m and the supply of power to th...

Page 13: ...feeding cable and the length of the cable between each unit If the feeding cables are short and the cables between the units are short more units can be connected than if the feeding cable is long an...

Page 14: ...th of Feeding Cable Type CAT5e AWG24 Length of inter connecting Cable Type CAT5e AWG24 Total cable length Max number of DC 6990 P pr output 10 m 1 m 35 m 26 30 m 1 m 53 m 24 50 m 1 m 70 m 21 100 m 1 m...

Page 15: ...terpreter Units connected The numbers are with no loudspeakers connected Note The number of units is dependent of how many interpreter sets there are per booth or language as there only can be one set...

Page 16: ...DCS 6000 Digital Conference System User Manual 16 Typical schematics The following schematics are showing a typical configuration with use of EX 6010 Figure 0 A System with EX 6010...

Page 17: ...2 pieces RJ45 DCS LAN repeated output 4 pieces RJ45 Cabling and System Limits Cable type min specification Cat5e AWG 24 shielded Maximum cable length in one chain 200 m System Environmental Conditions...

Page 18: ...BLU 5 0V BLU WHT BLU WHT 6 48V GRN GRN 7 Outgoing BRN WHT BRN WHT 8 Outgoing BRN BRN Important If other color codes are used then the four pairs are connected as follows Pair 2 Pin 1 2 Pair 3 Pin 3 6...

Page 19: ...1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email inf...

Reviews: