background image

DIS Digital Conference System 

User Manual

 

 

3

 

Important 

Important Safeguards 

1

 

Read these instructions

 - All the safety and 

operating  instructions  should  be  read  before 
the apparatus or system is operated. 

2

 

Keep  these  instructions

  -  The  important 

safety  instructions  and operating instructions 
should be retained for future reference. 

3

 

Heed  all  warnings

  -  All  warnings  on  the 

apparatus  and  in  the  operating  instructions 
should be adhered to. 

4

 

Follow all instructions

 - All instructions for 

installation  or  use/operating  should  be 
followed. 

5

 

Do not use this apparatus near water

 - Do 

not use this apparatus in a water or moistures 
environment  -  for  example,  near  a  bath  tub, 
wash bowl, kitchen sink, or laundry tub, in a 
wet  basement,  near  a  swimming  pool,  in  an 
unprotected  outdoor  installation,  or  any  area 
which is classified as a wet location. 

6

 

Warning:  To  reduce  the  risk  of  fire  or 
electric  shock,  do  not  expose  this 
apparatus  to  rain  or  moisture  and  no 
objects filled with liquids, such as vases, 
should be placed on this apparatus.   

7

 

Clean  only  with  dry  cloth

  -  Unplug  the 

apparatus from the outlet before cleaning. Do 
not use liquid cleaners or aerosol cleaners. 

8

 

Do  not  block  any  ventilation  openings. 
Install 

in 

accordance 

with 

the 

manufacturer’s  instructions

  -  Openings  in 

the  enclosure,  if  any,  are  provided  for 
ventilation and to ensure reliable operation of 
the  apparatus  and  to  protect  it  from 
overheating.  These  openings  must  not  be 
blocked or covered. This apparatus should not 
be  placed  in  a  built-in  installation  unless 
proper 

ventilation 

is 

provided 

or 

the 

manufacturer’s 

instructions 

have 

been 

adhered to. 

9

 

Do not install near any heat sources such 
as  radiators,  heat  registers,  stoves,  air 
ducts,  or  other  apparatus  (including 
amplifiers) that produce heat. 

10

 

Do not install the unit in a place exposed 
to  direct  sunlight,  excessive  dust  or 
humidity, mechanical vibration or shock

11

 

To  avoid  moisture  condensations  do 
not 

install 

the 

unit 

where 

the 

temperature may rise rapidly. 

12

 

Do not defeat the safety purpose of the 
polarized  or  ground-type  plug.

  A 

polarized  plug  has  two  blades  with  one 
wider than the other. A grounding type plug 
has  two  blades  and  a  third  grounding 
prong. The wider blade or the third prong is 
provided  for  your  safety.  If  the  provided 
plug does not fit into your outlet, consult an 
electrician for replacement of the obsolete 
outlet. 

13

 

Protect  the  power  cord  from  being 
walked  on  or  pinched  particularly  at 
plug, convenience receptacles, and the 
point  where  they  exit  from  the 
apparatus. 

14

 

Only 

use 

attachments/accessories 

specified  by  the  manufacturer

.  Any 

mounting  of  the  apparatus  should  follow 
the manufacturer’s instructions, and should 
use a mounting accessory recommended by 
the manufacturer. 

15

 

Use  only  with  the  cart,  stand,  tripod, 
bracket  or  table  specified  by  the 
manufacturer, 

or 

sold 

with 

the 

apparatus. 

When a cart is used, use caution when moving 

the cart/apparatus combination to avoid 
injury from tip-over - Quick stops, 
excessive force, and uneven surfaces may 
cause the appliance and cart combination 

to overturn. 

16

 

Unplug  this  apparatus 

during  lighting  storms  or 
when 

unused 

for 

long 

periods 

of 

time

– 

Not 

applicable 

when 

special 

functions are to be maintained, 
such as evacuation systems. 

17

 

Refer  all  servicing  to  qualified  service 
personnel.  Servicing  is  required  when 
the  apparatus  has  been  damaged  in 
any way, such as power-supply cord or 
plug  is  damaged,  liquid  has  been 
spilled  or  objects  have  fallen  into  the 

Summary of Contents for EX 6010

Page 1: ...2015 Shure Incorporated User Manual EX 6010 rev I English docx Conferencing and Discussion Systems EX 6010 Extension Unit USER GUIDE...

Page 2: ...CS 6000 system 6 System components 7 Central equipment etc 7 Interpreter equipment 7 Conference units and Ch selectors 7 Accessories 7 General Description 8 Features 8 Operating instruction 9 User Con...

Page 3: ...ear any heat sources such as radiators heat registers stoves air ducts or other apparatus including amplifiers that produce heat 10 Do not install the unit in a place exposed to direct sunlight excess...

Page 4: ...into the cabinet unplug the unit and have it checked by qualified personnel before operating it further Labels Lightning Flash Symbol with the lightning flash with arrowhead symbol within an equilate...

Page 5: ...nterference in which case the user will be required to correct the interference at his own expense Intentional or unintentional changes or modifications not expressly approved by the party responsible...

Page 6: ...nel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system Delegate and Interpreter units are powered and controlled by the CU 61xx Central Unit w...

Page 7: ...nference Unit portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DM 6620 F Conference Unit flush mounted with Chip card and 5 voting buttons CM DM 6680 F C...

Page 8: ...h are built into a 19 cabinet Repeater splitter board with 4 individual outputs 4 individual power supplies Features The main features of the EX 6010 Extension Unit are Built in Power Supplies for app...

Page 9: ...es when power is switched ON 2 Fault LED This indication lights up if the internal power supply is malfunctioning i e because of overheating or overload of a chain The Fault LED will always light up s...

Page 10: ...EX 6010 5 Repeated Chains 1 2 3 4 RJ45 connector 4 pieces Those connectors are DCS LAN connectors for connection to DM CM 6xxx IS 6132 CS 6032 EX 6010 AO 6004 6008 etc 6 Power LED s Those LED s light...

Page 11: ...reter sets for those languages have to be connected either to another EX 6010 Extension Unit which is connected to another of the four chains on the CU 6110 or directly to one other of the four chains...

Page 12: ...unlimited number of EX 6010 can be connected by using the Loop through connector However the practical limitation is the maximum cable length in one chain which is 200 m and the supply of power to th...

Page 13: ...feeding cable and the length of the cable between each unit If the feeding cables are short and the cables between the units are short more units can be connected than if the feeding cable is long an...

Page 14: ...th of Feeding Cable Type CAT5e AWG24 Length of inter connecting Cable Type CAT5e AWG24 Total cable length Max number of DC 6990 P pr output 10 m 1 m 35 m 26 30 m 1 m 53 m 24 50 m 1 m 70 m 21 100 m 1 m...

Page 15: ...terpreter Units connected The numbers are with no loudspeakers connected Note The number of units is dependent of how many interpreter sets there are per booth or language as there only can be one set...

Page 16: ...DCS 6000 Digital Conference System User Manual 16 Typical schematics The following schematics are showing a typical configuration with use of EX 6010 Figure 0 A System with EX 6010...

Page 17: ...2 pieces RJ45 DCS LAN repeated output 4 pieces RJ45 Cabling and System Limits Cable type min specification Cat5e AWG 24 shielded Maximum cable length in one chain 200 m System Environmental Conditions...

Page 18: ...BLU 5 0V BLU WHT BLU WHT 6 48V GRN GRN 7 Outgoing BRN WHT BRN WHT 8 Outgoing BRN BRN Important If other color codes are used then the four pairs are connected as follows Pair 2 Pin 1 2 Pair 3 Pin 3 6...

Page 19: ...1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email inf...

Reviews: