background image

DCS 6000  Digital Conference System 

User Manual

 

 

13

 

System Setup 

Installation 

The EX 6010 is suitable for either table-top or 
19-inch rack-mounted use. Two mounting 
brackets (for rack mounting) are supplied.  

When installing in a 19” rack the supplied 19” 
brackets shall be used.  

The unit has a low noise built-in fan taking air in 
at the left side of the unit and blowing the hot air 
out at the right side. That allows units in 19” 
racks to be stacked close with other units without 
extra room for cooling air between them.  

Please check that other units in the rack will 
allow this. 

Connect the EX 6010 to the various DCS 6000 
units using CAT5e cabling (F/UTP or U/FTP) 
shielded cables following the guidelines in the 
next chapter.   

The operation and installation of the various DCS 
6000 units is found in the User Manuals for the 
specific units. 

Cabling guidelines 

The Conference Units are connected to the CU 
61xx Central Unit using Cat5e F/UTP or U/FTP 
shielded cables and the following guidelines have 
to be observed: 

 

The  Conference  units  are  daisy  chain 
connected to the central unit  

 

The number of units, which can be connected 
to EX 6010, depends on length of the feeding 
cable and the length of the cable between each 
unit.  

If the feeding cables are short and the cables 
between the units are short, more units can 
be connected than if the feeding cable is long 
and/or the cables are long between the units.  

 

Maximum cable length in one chain is 200 m 
(before using EX 6010 or a RP 6004 Repeater 
in  a  chain).  This  includes  interconnection 
cables between the units.  

 

Maximum cable length in one chain when using 
EX  6010  or  RP  6004  Repeaters  and  Cat5e 
cables is 680 m. 

 

Cables must be AWG24 if the number of units 
in the tables in section ‘

0

 

 

’ is to be used. AWG26 cables will not allow as 
many units. DIS cables series EC 6001-xx are 
all AWG 24. 

 

It  is  desirable  that  the  square  of  the  feeding 
cables  is  as  big  as  possible  to  minimize  the 
voltage  drop  in  the  cables.  Cat5e  cables  are 
delivered in various gauges: 

The following table shows the 
Diameter/square for various AWG types: 

Type 

Diameter 

Square 

AWG22 

0.64 mm 

0.32 mm2 

AWG23/1 

0.57 mm 

0.25 mm2 

AWG24 

0.53 mm 

0.22 mm2 

AWG26 

0.42 mm 

0.14 mm2 

 

Although the DCS-LAN chain output connectors 
have a 125 W supply, this 125 W power is not all 
available with long cables, as there will be a 
power drop in the feeding cable from the EX 
6010 to the units connected.  

Please consult the next sections for details about 
the number of units, which can be connected 
depending on the cable length. 

 

 

Summary of Contents for EX 6010

Page 1: ...2015 Shure Incorporated User Manual EX 6010 rev I English docx Conferencing and Discussion Systems EX 6010 Extension Unit USER GUIDE...

Page 2: ...CS 6000 system 6 System components 7 Central equipment etc 7 Interpreter equipment 7 Conference units and Ch selectors 7 Accessories 7 General Description 8 Features 8 Operating instruction 9 User Con...

Page 3: ...ear any heat sources such as radiators heat registers stoves air ducts or other apparatus including amplifiers that produce heat 10 Do not install the unit in a place exposed to direct sunlight excess...

Page 4: ...into the cabinet unplug the unit and have it checked by qualified personnel before operating it further Labels Lightning Flash Symbol with the lightning flash with arrowhead symbol within an equilate...

Page 5: ...nterference in which case the user will be required to correct the interference at his own expense Intentional or unintentional changes or modifications not expressly approved by the party responsible...

Page 6: ...nel Selectors Repeaters etc In practical use there are no limits for the number of Channel Selectors in a system Delegate and Interpreter units are powered and controlled by the CU 61xx Central Unit w...

Page 7: ...nference Unit portable with voting CM DM 6080 F Conference Unit flush mounted with built in channel selectors DM 6620 F Conference Unit flush mounted with Chip card and 5 voting buttons CM DM 6680 F C...

Page 8: ...h are built into a 19 cabinet Repeater splitter board with 4 individual outputs 4 individual power supplies Features The main features of the EX 6010 Extension Unit are Built in Power Supplies for app...

Page 9: ...es when power is switched ON 2 Fault LED This indication lights up if the internal power supply is malfunctioning i e because of overheating or overload of a chain The Fault LED will always light up s...

Page 10: ...EX 6010 5 Repeated Chains 1 2 3 4 RJ45 connector 4 pieces Those connectors are DCS LAN connectors for connection to DM CM 6xxx IS 6132 CS 6032 EX 6010 AO 6004 6008 etc 6 Power LED s Those LED s light...

Page 11: ...reter sets for those languages have to be connected either to another EX 6010 Extension Unit which is connected to another of the four chains on the CU 6110 or directly to one other of the four chains...

Page 12: ...unlimited number of EX 6010 can be connected by using the Loop through connector However the practical limitation is the maximum cable length in one chain which is 200 m and the supply of power to th...

Page 13: ...feeding cable and the length of the cable between each unit If the feeding cables are short and the cables between the units are short more units can be connected than if the feeding cable is long an...

Page 14: ...th of Feeding Cable Type CAT5e AWG24 Length of inter connecting Cable Type CAT5e AWG24 Total cable length Max number of DC 6990 P pr output 10 m 1 m 35 m 26 30 m 1 m 53 m 24 50 m 1 m 70 m 21 100 m 1 m...

Page 15: ...terpreter Units connected The numbers are with no loudspeakers connected Note The number of units is dependent of how many interpreter sets there are per booth or language as there only can be one set...

Page 16: ...DCS 6000 Digital Conference System User Manual 16 Typical schematics The following schematics are showing a typical configuration with use of EX 6010 Figure 0 A System with EX 6010...

Page 17: ...2 pieces RJ45 DCS LAN repeated output 4 pieces RJ45 Cabling and System Limits Cable type min specification Cat5e AWG 24 shielded Maximum cable length in one chain 200 m System Environmental Conditions...

Page 18: ...BLU 5 0V BLU WHT BLU WHT 6 48V GRN GRN 7 Outgoing BRN WHT BRN WHT 8 Outgoing BRN BRN Important If other color codes are used then the four pairs are connected as follows Pair 2 Pin 1 2 Pair 3 Pin 3 6...

Page 19: ...1212 USA Fax 1 847 600 6446 Email info shure com Europe Middle East Africa Shure Europe Gmbh Jakob Dieffenbacher Str 12 75031 Eppingen Germany Phone 49 0 7262 9249 100 Fax 49 0 7262 9249 114 Email inf...

Reviews: