background image

 

  

 

 

   

 

Order code: 34040 

ACT Flood 80 RGBW 

Before the initial start-up, please make sure that there is no damage caused by transportation. Should 
there be any, consult your dealer and do not use the device. 
 
To maintain perfect condition and to ensure a safe operation, it is absolutely necessary for the user to 
follow the safety instructions and warning notes contained in this manual. 
 
Please consider that damages caused by manual modifications to the device are not subject to 
warranty. 
 
This device contains no user-serviceable parts. Refer servicing to qualified technicians only. 
 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never modify, bend, mechanically strain, put pressure on, pull or heat up the power cord. 

 

Never strain the cable insert. There must always be sufficient cable going to the device. Otherwise, 
the cable will be damaged, which can cause serious damage. 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never place any material over the lens. 

 

Never look directly into the light source. 

 

Never leave any cables lying around. 

 

Do not connect this device to a dimmer pack. 

 

Do not switch the device on and off in short intervals, as this will reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation (housing becomes very hot). 
Allow the fixture to cool for at least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use the device indoors, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly 
fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep the covers closed while operating. 

 

Always allow free space of at least 0,5 m around the unit for ventilation. 

 

Always disconnect power from the mains when device is not used or before cleaning! Only handle 
the power cord holding it by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If the lens is obviously damaged, it has to be replaced to prevent its functions from being impaired, 
due to cracks or deep scratches. 

 

If device was dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water may damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue the use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. The device must be installed beyond the reach of children. Never leave the unit 
running unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

For replacement use fuses of same type and rating only. 

 

The user is responsible for correct positioning and operating of the device. The manufacturer will not 
accept liability for damages caused by the misuse or incorrect installation of this device. 

Summary of Contents for ACT Flood 80 RGBW

Page 1: ...ACT Flood 80 RGBW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Order code 34040 MANUAL ENGLISH...

Page 2: ...ling 12 Control Panel 13 DMX Addressing 13 Main Menu Overview 14 Start up 15 Main Menu Options 15 1 DMX Functions 15 1 1 DMX Address 16 1 2 DMX Channel Mode 16 1 3 DMX Fail 16 1 4 View DMX Value 17 2...

Page 3: ...des Showtec ACT Flood 80 RGBW Barndoor Schuko to Pro power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the ac...

Page 4: ...ater or other liquids Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly fastened Only operate the device after having familiarized with its funct...

Page 5: ...inimum distance between light output and the illuminated surface must be bigger than 1 m In order to eliminate wear and improve the device s lifespan during periods of non use completely disconnect fr...

Page 6: ...The installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the device always make sure that the area below the...

Page 7: ...per UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your add...

Page 8: ...l theatres galleries TV studios and events Input voltage 100 240 V AC 50 60 Hz Power consumption 85W Light source 1 x 80 W RGBW Quad LED Beam angle 95 105 Output 1540 lx 2 m Color temperature 2800K to...

Page 9: ...nu buttons 04 Manual Color Select 05 Manual Dimmer 06 3 pin DMX signal connector IN 07 Fuse T2 AL 250V 08 Pro power connector IN 100 240 V 7A 50 60 Hz Blue 09 Pro power connector OUT 100 240 V 7A 50 6...

Page 10: ...cation product on 230 V power or vice versa Connect the device to the main power supply Multiple Fixtures Power Linking The ACT Flood 80 RGBW supports power linking Power can be relayed to another dev...

Page 11: ...om 0 to 100 The current value of the dimmer is displayed on the screen Note If you do not return to the start screen you cannot adjust the dimmer The manual dimmer control 5 is not functional if you d...

Page 12: ...socket using a DMX cable Connect the first unit s out socket with the second unit s in socket using a DMX cable Repeat this process to link the rest of the units 05 Supply electric power Plug electri...

Page 13: ...gnal Maximum recommended DMX data link distance 100 meters Maximum recommended number of fixtures on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You...

Page 14: ...tc Make sure that you do not have any overlapping channels in order to control each ACT Flood correctly If two or more ACT Floods are addressed similarly they will work similarly Controlling After hav...

Page 15: ...14 Order code 34040 ACT Flood 80 RGBW Main Menu Overview...

Page 16: ...e through the menus or to increase decrease numeric values Use the ENTER button to open the desired menu to confirm your choice or to set the currently selected value Note If no button is pressed afte...

Page 17: ...mode There are 3 options available 02 Press the ENTER button to confirm the selection 1 3 DMX Fail In this pop up submenu you can determine the behavior of the device in case of a DMX signal failure 0...

Page 18: ...gs In this menu you can select how the device will be operated manually 03 Press the UP DOWN buttons to scroll through the following options 04 Press the ENTER button to confirm your choice 2 1 Contro...

Page 19: ...button to open the pop up submenu for the desired show mode 02 You can choose 2 different sub menus 03 Press the ENTER button to open the pop up submenu for the desired show mode If you have chosen S...

Page 20: ...een Linear Square Law Inverse Square Law and S Curve Dimmer Speed There are 2 options available LED instant dimming without delay and Halogen delayed dimming imitating the behavior of a halogen lamp 0...

Page 21: ...NTER button to confirm your choice 4 Display Settings In this menu you can adjust the display settings of the device 01 Press the UP DOWN buttons to scroll through the following options 02 Press the E...

Page 22: ...uttons to toggle between Red Green Blue White Dimmer and Strobe 02 Press the ENTER button to confirm your selection and open the respective pop up submenus where you can adjust the values 03 Press the...

Page 23: ...set between 20 255 0 255 Gradual adjustment White from 0 100 Channel 5 Color Temp CH6 must be open and CH7 must be set between 20 255 0 255 Color Temp from 2800 to 7200K Channel 6 Dimmer CH1 2 3 or 4...

Page 24: ...cro CH7 must be open and CH9 must be set between 20 255 0 No Function 1 4 Color 1 5 8 Color 2 9 12 Color 3 245 248 Color 62 249 252 Color 63 253 255 Color 64 Channel 6 Color Temp CH7 must be open and...

Page 25: ...rom fast to slow 185 189 Open 190 204 Random Burst Pulse from fast to slow 205 209 Open 210 224 Slow close to slow open from fast to slow 225 229 Open 230 244 Burst little from fast to slow 245 255 Op...

Page 26: ...c power source 02 Insert a screwdriver into the slot of the fuse cover Turn the fuse holder counterclockwise The fuse holder will come out 03 Remove the used fuse If brown or unclear it is burned out...

Page 27: ...data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in the DMX...

Page 28: ...urce 1 x 80 W RGBW Quad LED Dimmer 0 100 Strobe effect Yes Beam angle 95 105 Output 1540 lx 2 m Color temperature 2800K to 10000K Housing Extruded aluminum Color Black Display OLED DMX control Via sta...

Page 29: ...28 Order code 34040 ACT Flood 80 RGBW Dimensions...

Page 30: ...29 Order code 34040 ACT Flood 80 RGBW...

Page 31: ...30 Order code 34040 ACT Flood 80 RGBW...

Page 32: ...2020 Showtec...

Reviews: