Order code: 34040 

ACT Flood 80 RGBW 

105–109 

Open 

110–124 

Random strobe, from fast to slow 

125–129 

Open 

130–144 

Random Strobe Fast close to slow open, from fast to slow 

145–149 

Open 

150–164 

Random Strobe Slow close to fast open, from fast to slow 

165–169 

Open 

170–184 

Burst Pulse, from fast to slow 

185–189 

Open 

190–204 

Random Burst Pulse, from fast to slow 

205–209 

Open 

210–224 

Slow close to slow open, from fast to slow 

225–229 

Open 

230–244 

Burst little, from fast to slow 

245–255 

Open 

 

Channel 10 – Built-in Programs 

 CH7 must be open and CH9 must be set between 20-255 

 

0–3 

No function 

4–127 

Color 1 – Color 32 

128–191 

Color Switch 1 – 16 

192–255 

Color Fade 1 -16 

 

Channel 11 – Program Speed 

 CH10 must be set between 128-255 

 

0–255 

From slow to fast (Color Switch & Color Fade) 

 

 

Summary of Contents for ACT Flood 80 RGBW

Page 1: ...ACT Flood 80 RGBW V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Order code 34040 MANUAL ENGLISH...

Page 2: ...ling 12 Control Panel 13 DMX Addressing 13 Main Menu Overview 14 Start up 15 Main Menu Options 15 1 DMX Functions 15 1 1 DMX Address 16 1 2 DMX Channel Mode 16 1 3 DMX Fail 16 1 4 View DMX Value 17 2...

Page 3: ...des Showtec ACT Flood 80 RGBW Barndoor Schuko to Pro power cable 1 5 m User manual LED Expected Lifespan LEDs gradually decline in brightness over time HEAT is the dominant factor that leads to the ac...

Page 4: ...ater or other liquids Only operate the fixture after having checked if the housing is firmly closed and all screws are tightly fastened Only operate the device after having familiarized with its funct...

Page 5: ...inimum distance between light output and the illuminated surface must be bigger than 1 m In order to eliminate wear and improve the device s lifespan during periods of non use completely disconnect fr...

Page 6: ...The installation must always be secured with a safety attachment e g an appropriate safety net or safety cable When rigging derigging or servicing the device always make sure that the area below the...

Page 7: ...per UPS packing or double boxing is always a safe method to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 01 Your name 02 Your add...

Page 8: ...l theatres galleries TV studios and events Input voltage 100 240 V AC 50 60 Hz Power consumption 85W Light source 1 x 80 W RGBW Quad LED Beam angle 95 105 Output 1540 lx 2 m Color temperature 2800K to...

Page 9: ...nu buttons 04 Manual Color Select 05 Manual Dimmer 06 3 pin DMX signal connector IN 07 Fuse T2 AL 250V 08 Pro power connector IN 100 240 V 7A 50 60 Hz Blue 09 Pro power connector OUT 100 240 V 7A 50 6...

Page 10: ...cation product on 230 V power or vice versa Connect the device to the main power supply Multiple Fixtures Power Linking The ACT Flood 80 RGBW supports power linking Power can be relayed to another dev...

Page 11: ...om 0 to 100 The current value of the dimmer is displayed on the screen Note If you do not return to the start screen you cannot adjust the dimmer The manual dimmer control 5 is not functional if you d...

Page 12: ...socket using a DMX cable Connect the first unit s out socket with the second unit s in socket using a DMX cable Repeat this process to link the rest of the units 05 Supply electric power Plug electri...

Page 13: ...gnal Maximum recommended DMX data link distance 100 meters Maximum recommended number of fixtures on a DMX data link 30 fixtures Data Cabling To link fixtures together you must obtain data cables You...

Page 14: ...tc Make sure that you do not have any overlapping channels in order to control each ACT Flood correctly If two or more ACT Floods are addressed similarly they will work similarly Controlling After hav...

Page 15: ...14 Order code 34040 ACT Flood 80 RGBW Main Menu Overview...

Page 16: ...e through the menus or to increase decrease numeric values Use the ENTER button to open the desired menu to confirm your choice or to set the currently selected value Note If no button is pressed afte...

Page 17: ...mode There are 3 options available 02 Press the ENTER button to confirm the selection 1 3 DMX Fail In this pop up submenu you can determine the behavior of the device in case of a DMX signal failure 0...

Page 18: ...gs In this menu you can select how the device will be operated manually 03 Press the UP DOWN buttons to scroll through the following options 04 Press the ENTER button to confirm your choice 2 1 Contro...

Page 19: ...button to open the pop up submenu for the desired show mode 02 You can choose 2 different sub menus 03 Press the ENTER button to open the pop up submenu for the desired show mode If you have chosen S...

Page 20: ...een Linear Square Law Inverse Square Law and S Curve Dimmer Speed There are 2 options available LED instant dimming without delay and Halogen delayed dimming imitating the behavior of a halogen lamp 0...

Page 21: ...NTER button to confirm your choice 4 Display Settings In this menu you can adjust the display settings of the device 01 Press the UP DOWN buttons to scroll through the following options 02 Press the E...

Page 22: ...uttons to toggle between Red Green Blue White Dimmer and Strobe 02 Press the ENTER button to confirm your selection and open the respective pop up submenus where you can adjust the values 03 Press the...

Page 23: ...set between 20 255 0 255 Gradual adjustment White from 0 100 Channel 5 Color Temp CH6 must be open and CH7 must be set between 20 255 0 255 Color Temp from 2800 to 7200K Channel 6 Dimmer CH1 2 3 or 4...

Page 24: ...cro CH7 must be open and CH9 must be set between 20 255 0 No Function 1 4 Color 1 5 8 Color 2 9 12 Color 3 245 248 Color 62 249 252 Color 63 253 255 Color 64 Channel 6 Color Temp CH7 must be open and...

Page 25: ...rom fast to slow 185 189 Open 190 204 Random Burst Pulse from fast to slow 205 209 Open 210 224 Slow close to slow open from fast to slow 225 229 Open 230 244 Burst little from fast to slow 245 255 Op...

Page 26: ...c power source 02 Insert a screwdriver into the slot of the fuse cover Turn the fuse holder counterclockwise The fuse holder will come out 03 Remove the used fuse If brown or unclear it is burned out...

Page 27: ...data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination plug Insert termination plug in the DMX...

Page 28: ...urce 1 x 80 W RGBW Quad LED Dimmer 0 100 Strobe effect Yes Beam angle 95 105 Output 1540 lx 2 m Color temperature 2800K to 10000K Housing Extruded aluminum Color Black Display OLED DMX control Via sta...