- 30 -
Follow the following procedures to recover operation when breakers operate
due to overcurrent.
1) Turn off all switches of devices using the equipment as an AC power source.
2) Push up the breaker lever that have operated to the "ON" position.
<<<<
Note
>>>>
•
Refer to section "9-2
.
Usable Device Capacities" and be careful of overloading.
•
Due to the fact that breakers only function for AC power output, the engine can
become overloaded if simultaneously welding and using the equipment as an AC
power source.
Refer to the table below and limit the use of AC power accordingly.
Overview of Capacities Usable Simultaneously
(
50
/
60Hz
)
Weld Output
AC Power Output
Amount of
Personnel
Welding
Rod
Current
3-Phase
(Power Factor 0.8)
1-Phase
(Power Factor 1.0)
φ
2.0
60A
10.5
/
12 kVA
8.5
/
10 kW
φ
2.6
120A
8.5
/
10 kVA
7.0
/
8.5 kW
φ
3.2
140A
7.5
/
9.5 kVA
6.0
/
8.0 kW
φ
4.0
170A
6.0
/
8.5 kVA
5.0
/
7.0 kW
φ
5.0
240A
3.0
/
5.5 kVA
2.5
/
4.5 kW
φ
6.0
300A
1.0
/
2.5 kVA
0.5
/
2.0 kW
U
se
d
b
y
1
P
e
rs
o
n
"
S
IN
G
L
E
"
o
r
"
D
U
A
L
"
φ
8.0
380A
0
/
0 kVA
0
/
0 kW
φ
2.0
60Ax2
8.5
/
10.5 kVA
7.0
/
8.5 kW
φ
2.6
120Ax2
4.0
/
6.5 kVA
3.5
/
5.5 kW
φ
3.2
140Ax2
3.0
/
5.0 kVA
2.5
/
4.0 kW
U
s
e
d
b
y
2
P
e
rs
o
n
s
"
D
U
A
L
"
φ
4.0
170Ax2
PLUS
1.0
/
2.5 kVA
OR
0.5
/
2.0 kW
* 1-Phase output is the total output of three receptacles.
<<<<
Note
>>>>
•
Do use as an AC power source simultaneously with welding if it is necessary to
perform high-quality welding.
•
Warning: Electric Shock/Injury
•
Do not touch the equipment during operation if the equipment or your
body is wet.
•
Always be sure to stop the engine and remove the starter key before
performing any equipment check or maintenance.
•
Do not operate the equipment with any doors or covers open. There is a
danger of hair, body parts and other items being caught up in moving
parts such as cooling fans and belts.
•
Do not modify the equipment and do not operate with parts removed.
10.
Simultaneously Welding and Using as AC Power Source
11. Inspection/Maintenance
Summary of Contents for DGW400DM-C
Page 2: ......
Page 44: ...41 14 Engine Wiring Diagram...
Page 45: ...42 15 Generator Wiring Diagram...
Page 46: ...43...
Page 47: ...44...
Page 48: ...45 2013...